Mechanobiology in the management of mobile atrophic and oligotrophic tibial nonunions

被引:8
作者
Ferreira, Nando [1 ]
Marais, Leonard Charles [1 ]
Aldous, Colleen [2 ]
机构
[1] Univ KwaZulu Natal, Tumour Sepsis & Reconstruct Unit, Dept Orthopaed Surg, Greys Hosp,Nelson R Mandela Sch Med, ZA-3201 Durban, South Africa
[2] Univ KwaZulu Natal, Sch Clin Med, Coll Hlth Sci, ZA-4051 Durban, South Africa
关键词
Ilizarov; TrueLok; Nonunion; Atrophic; Circular external fixator;
D O I
10.1016/j.jor.2015.10.012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Recent research indicates that atrophic nonunions are biologically active and may heal in the optimal biomechanical environment. Methods: Thirty-three patients with mobile atrophic and oligotrophic tibial nonunions were treated with circular external fixation and functional rehabilitation. Seven patients required autogenous bone graft procedures. Results: Bony union was achieved after the initial surgery in 31/33 (93.9%) tibias. Two persistent nonunions were successfully treated with repeat circular external fixation without bone graft. This resulted in final bony union in 33/33 (100%) patients. Conclusion: Mechanobiological stimulation of tibial nonunions can produce union even if the biological activity appears to be low. (C) 2015 Prof. PK Surendran Memorial Education Foundation. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:S182 / S187
页数:6
相关论文
共 38 条
[1]  
Bhandari M, 2000, CURRENT OPINION ORTH, V11, P372, DOI DOI 10.1097/00001433-200010000-00008
[2]   Autograft versus BMPs for the treatment of non-unions: What is the evidence? [J].
Blokhuis, Taco J. ;
Calori, Giorgio M. ;
Schmidmaier, Gerhard .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 :S40-S42
[3]   The vascularity of atrophic non-unions [J].
Brownlow, HC ;
Reed, A ;
Simpson, AHRW .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2002, 33 (02) :145-150
[4]   Metabolic activity of a new atrophic nonunion model in rabbits [J].
Brownlow, HC ;
Simpson, AHRW .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2000, 18 (03) :438-442
[5]  
Butt MF, 2006, INDIAN J ORTHOP, V40, P247, DOI [10.4103/0019-5413.34505, DOI 10.4103/0019-5413.34505]
[6]   Comparison of the mechanical performance of three types of external fixators: Linear, circular and hybrid [J].
Caja, VL ;
Kim, W ;
Larsson, S ;
Chao, EYS .
CLINICAL BIOMECHANICS, 1995, 10 (08) :401-406
[7]  
Carter DR, 1998, CLIN ORTHOP RELAT R, pS41
[8]  
Cech O, 1976, PSEUDARTHROSIS
[9]  
Checketts RG, 2000, ORTHOFIX EXTERNAL FIXATION IN TRAUMA AND ORTHOPAEDICS, P97
[10]  
CHEN J.C., 2005, CURRENT OPINION ORTH, V16, P338