INTERCOOLED LOW-PRESSURE TURBO STEAM-INJECTION GAS-TURBINE WITH COGENERATION

被引:0
|
作者
NAJJAR, YSH
NAHAS, MN
机构
[1] King Abdul Aziz Univ, Jeddah, Saudi Arabia
来源
JOURNAL OF THE INSTITUTE OF ENERGY | 1994年 / 67卷 / 470期
关键词
Cogeneration plants - Efficiency - Performance - Sensitivity analysis - Thermal effects;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Combined-cycle power plants seem an almost ideal solution for coping with demands for electrical power and heat: they give unique flexibility over wide ranges of loading. The gas turbine, because of its ability to burn a variety of fuels, may become the work-horse of all expanding electricity-supply systems. In this paper a system of intercooled low-pressure steam-injected gas turbine (turbo-STIG) with cogeneration is compared with an intercooled cogenerated one. Design point thermo-economic evaluation shows that the first out-performs the second by about 21% in power output and 16% in overall efficiency, with a payback period of 1.5 years. Off-design performance and useful energy in the bled steam were evaluated over wide ranges of the operating variables, namely compressor pressure ratio, turbine inlet temperature and injected steam:air ratio. A comparison between the two systems demonstrates the superiority of the first system. Sensitivity analysis shows the remarkable effect of turbine inlet temperature on the energy in the bled steam.