QUALITATIVE AND QUANTITATIVE RESPONSE CHARACTERISTICS OF A CAPILLARY GAS-CHROMATOGRAPH ION MOBILITY SPECTROMETER TO HALOGENATED COMPOUNDS

被引:21
作者
KARPAS, Z [1 ]
WANG, YF [1 ]
EICEMAN, GA [1 ]
机构
[1] NEW MEXICO STATE UNIV,DEPT CHEM,LAS CRUCES,NM 88003
关键词
GAS CHROMATOGRAPHY; CAPILLARY GC; ION MOBILITY SPECTROMETER; HALOGENATED COMPOUNDS;
D O I
10.1016/0003-2670(93)80348-O
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The response of a capillary column gas chromatograph/ion mobility spectrometer (GC/IMS) system to chlorinated and brominated alkanes and alkenes in nitrogen, air and nitrogen/CO2 mixtures was studied. Product ions were formed through dissociative electron capture processes or charge transfer reactions, yielding chloride or bromide ions. The quantitative response was shown to depend on the composition of the carrier gas in which atmospheric pressure ionization processes occurred as well as on the IMS cell temperature. Large variations in the quantitative response of the GC/IMS to different halogenated compounds were observed. The results were compared to those reported for the doped electron capture detector (ECD). Practical implications of the GC/IMS system as a monitor and detector for halogenated aliphatic compounds are discussed.
引用
收藏
页码:19 / 31
页数:13
相关论文
共 34 条
[1]   HALOGENATED COMPOUND RESPONSE IN AN OXYGEN DOPED ION MOBILITY DETECTOR FOR CAPILLARY GAS-CHROMATOGRAPHY [J].
BAIM, MA ;
HILL, HH .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1983, 6 (01) :4-10
[2]   DETERMINATION OF 2,4-DICHLOROPHENOXYACETIC ACID IN SOILS BY CAPILLARY GAS-CHROMATOGRAPHY WITH ION-MOBILITY DETECTION [J].
BAIM, MA ;
HILL, HH .
JOURNAL OF CHROMATOGRAPHY, 1983, 279 (NOV) :631-642
[3]  
BERANT Z, 1989, J PHYS CHEM-US, V93, P7527
[4]   DISSOCIATIVE ELECTRON-TRANSFER - ABINITIO STUDY OF THE CARBON HALOGEN BOND REDUCTIVE CLEAVAGE IN METHYL AND PERFLUOROMETHYL HALIDES - ROLE OF THE SOLVENT [J].
BERTRAN, J ;
GALLARDO, I ;
MORENO, M ;
SAVEANT, JM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (24) :9576-9583
[5]  
COHEN MJ, 1970, J CHROMATOGR SCI, V8, P331
[6]  
DANYLEWYCHMAY LL, 1991, 1ST P INT S EXPL
[7]   ION MOBILITY DETECTION AFTER SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
EATHERTON, RL ;
MORRISSEY, MA ;
SIEMS, WF ;
HILL, HH .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1986, 9 (03) :154-160
[8]   ION MOBILITY SPECTROMETRY OF HALOTHANE, ENFLURANE, AND ISOFLURANE ANESTHETICS IN AIR AND RESPIRED GASES [J].
EICEMAN, GA ;
SHOFF, DB ;
HARDEN, CS ;
SNYDER, AP ;
MARTINEZ, PM ;
FLEISCHER, ME ;
WATKINS, ML .
ANALYTICAL CHEMISTRY, 1989, 61 (10) :1093-1099
[9]   ION IDENTITY AND TRANSPORT PROPERTIES IN CO2 OVER A WIDE PRESSURE RANGE [J].
ELLIS, HW ;
PAI, RY ;
GATLAND, IR ;
MCDANIEL, EW ;
WERNLUND, R ;
COHEN, MJ .
JOURNAL OF CHEMICAL PHYSICS, 1976, 64 (10) :3935-3941
[10]  
Fehsenfeld F C, 1981, ELECTRON CAPTURE THE, P69