Insulation coordination models are an essential part of power system studies and are used to determine the performance of a transmission line or substation. This paper generalizes the guidelines and parameters to be used in modelling the substation and in performing the analysis on the prediction of the transformer damage. Modelling parameters and the substation layout design are based and adapted from 132/11 kV Simpang Renggam - Ayer Hitam substation in Johor Baharu, Malaysia, courtesy of the Tenaga Nasional Berhad (TNB). The model is based on the single phase line model, as was suggested by the IEEE, to be adequate to represent the substation in transient analysis simulation. Extensive analyses on the placement of the surge arresters at the substation and a prediction of the transformer damage are also presented. The results obtained from this analysis are then compared with the suggested Basic Lightning Insulation Level (BIL) by the TNB, according to the standards, for assessing the percentage of transformer damage and optimizing the substation performance in terms of its reliability and cost effectiveness.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Modelling 132 kV substation for surge arrester studies
    Universiti Putra Malaysia
    Int. J. Emerg. Electr. Power Syst., 2008, 5
  • [2] Surge arrester requirements study for transformer protection in 132 W GIS substation
    Malek, Z. Abdul
    2007 CONFERENCE PROCEEDINGS IPEC, VOLS 1-3, 2007, : 494 - 499
  • [3] Analysis of discharge energy on surge arrester configurations in 132 kV double circuit transmission lines
    Hassan, Nor Hidayah Nor
    Abu Bakar, Ab Halim
    Illias, Hazlee Azil
    Abd Halim, Syahirah
    Mokhlis, Hazlie
    Terzija, Vladimir
    MEASUREMENT, 2019, 139 : 103 - 111
  • [4] Analytical and experimental studies on 245 kV gas insulated surge arrester
    Rao, M. Mohana
    Lanjewar, Archana
    Tiwari, Neelam
    ELECTRIC POWER SYSTEMS RESEARCH, 2022, 204
  • [5] Impact of shunt capacitor banks on substation surge environment and surge arrester applications
    Bostic, MM
    Leskovich, RT
    Pillmore, GA
    Comber, MG
    Lim, AL
    Seay, DE
    Huynh, H
    Lishchyna, L
    Skliutas, JP
    Johnnerfelt, B
    Mathews, HG
    Stump, KB
    Jones, RA
    Musa, YI
    Tarasiewicz, EJ
    Lee, GE
    Pargaonkar, V
    Thallum, TS
    IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (04) : 1798 - 1809
  • [6] Modeling and simulation of a metal oxide lightning surge arrester for 132kV overhead transmission lines
    Khan, Aziz Ullah
    European Journal of Electrical Engineering, 2020, 22 (4-5) : 389 - 394
  • [7] Experience and long term performance of 132kV overhead lines gapless-type surge arrester
    Rawi, Iryani Mohamed
    Yahaya, Mohd Pauzi
    Ab Kadir, M. Z. A.
    Azis, Norhafiz
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 517 - 520
  • [8] Modelling and Simulation of a Surge Arrester in the Physical Domain
    Gonzalez-A, Gilberto
    2014 19TH INTERNATIONAL CONFERENCE ON METHODS AND MODELS IN AUTOMATION AND ROBOTICS (MMAR), 2014, : 76 - 81
  • [9] Soil Improvement for currents dissipation through substation surge arrester on earthing system in LT 138 kV Barreiras - Rio Grande
    Maurilio, Silva J.
    Mario, Pinheiro J. C.
    2015 INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (XIII SIPDA), 2015, : 141 - 145
  • [10] Grading Structure Design of Surge Arrester for 1000-kV Ultra-high Voltage Air-insulated Substation
    He, Jinliang
    Hu, Jun
    Zhang, Bo
    ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION, 2008, : 84 - 87