DETERMINATION OF 2-THIOTHIAZOLIDINE-4-CARBOXYLIC ACID IN URINE BY LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION

被引:11
作者
CIUCU, A
BALDWIN, RP
机构
[1] UNIV LOUISVILLE,DEPT CHEM,LOUISVILLE,KY 40292
[2] UNIV BUCHAREST,DEPT ANALYT CHEM,BUCHAREST,ROMANIA
关键词
AMPEEROMETRIC DETECTION; 2-THIOTHIAZOLIDINE-4-CARBOXYLIC ACID; MODIFIED ELECTRODE;
D O I
10.1002/elan.1140040420
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An assay procedure utilizing liquid chromatography and amperometric detection at a chemically modified electrode (CME) has been developed for the determination of 2-thiothiazolidine-4-carboxylic acid (TTCA) in urine samples. The electrocatalytic activity of the CME, which consisted of a glassy carbon surface coated with an electropolymerized cobalt phthalocyanine film, permitted optimum response at a potential of +0.75 V vs. Ag/AgCl with a detection limit of 7 pmol for TTCA and with no sample preparation required. In case of fouling of the electrode surface by sample constituents, the polymeric cobalt phthalocyanine electrode surface could be renewed with a variability of less than 10% and an equilibration time of less than 15 minutes.
引用
收藏
页码:515 / 519
页数:5
相关论文
共 26 条
[1]   SYNTHESIS AND STRUCTURAL STUDIES OF METAL(II) 4,9,16,23-PHTHALOCYANINE TETRAAMINES [J].
ACHAR, BN ;
FOHLEN, GM ;
PARKER, JA ;
KESHAVAYYA, J .
POLYHEDRON, 1987, 6 (06) :1463-1467
[2]   PHTHALOCYANINE POLYMERS .4. NOVEL TYPE OF THERMALLY STABLE POLYIMIDES DERIVED FROM METAL PHTHALOCYANINE TETRAMINES AND BENZOPHENONE TETRACARBOXYLIC DIANHYDRIDE [J].
ACHAR, BN ;
FOHLEN, GM ;
PARKER, JA .
JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 1982, 20 (10) :2773-2780
[3]   CHEMICALLY MODIFIED ELECTRODES IN LIQUID-CHROMATOGRAPHY DETECTION - A REVIEW [J].
BALDWIN, RP ;
THOMSEN, KN .
TALANTA, 1991, 38 (01) :1-16
[4]   EVALUATION OF OCCUPATIONAL EXPOSURE TO CARBON-DISULFIDE BY BLOOD, EXHALED AIR, AND URINE ANALYSIS [J].
CAMPBELL, L ;
JONES, AH ;
WILSON, HK .
AMERICAN JOURNAL OF INDUSTRIAL MEDICINE, 1985, 8 (02) :143-153
[5]  
DEBAUN JR, 1974, XENOBIOTICA, V2, P101
[6]   THE APPLICATION OF CHEMICALLY MODIFIED ELECTRODES IN ANALYTICAL-CHEMISTRY [J].
DONG, SJ ;
WANG, YD .
ELECTROANALYSIS, 1989, 1 (02) :99-106
[7]  
FIELDER RJ, 1981, TOXICITY REV, V3
[8]   DETERMINATION OF CYSTEINE AND GLUTATHIONE IN PLASMA AND BLOOD BY LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION USING A CHEMICALLY MODIFIED ELECTRODE CONTAINING COBALT PHTHALOCYANINE [J].
HALBERT, MK ;
BALDWIN, RP .
JOURNAL OF CHROMATOGRAPHY, 1985, 345 (01) :43-49
[9]   ELECTROCATALYTIC AND ANALYTICAL RESPONSE OF COBALT PHTHALOCYANINE CONTAINING CARBON PASTE ELECTRODES TOWARD SULFHYDRYL COMPOUNDS [J].
HALBERT, MK ;
BALDWIN, RP .
ANALYTICAL CHEMISTRY, 1985, 57 (03) :591-595
[10]  
KALBERT M, 1985, ANAL CHEM, V57, P591