IMPACT OF SHOCK-WAVE PATTERN AND CAVITATION BUBBLE-SIZE ON TISSUE-DAMAGE DURING URETEROSCOPIC ELECTROHYDRAULIC LITHOTRIPSY

被引:26
作者
VORREUTHER, R
CORLEIS, R
KLOTZ, T
BERNARDS, P
ENGELMANN, U
机构
[1] Department of Urology, University of Cologne, Cologne
[2] Requests for reprints: Department of Urology, University of Cologne, 50924 Cologne
关键词
LITHOTRIPSY; URETERAL CALCULI;
D O I
10.1016/S0022-5347(01)67734-6
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
It is known that electrohydraulic lithotripsy (EHL) during ureteroscopy may cause ureteral damage. To evaluate this trauma potential, find its mechanism and make it possible to avoid it, our research employed photographic evaluation, tissue studies, shock wave measurements and disintegration tests. The setup included a 3.3 F probe attached to an experimental generator with adjustable voltages and capacities providing energies from 25 mJ. to 1300 mJ. per pulse. In general, we distinguish between two traumatic mechanisms: (1) After placing the probe directly on the mucosa the rapid initial plasma penetrates the tissue resulting in a small, nonthermal, punched-like defect, whose depth depends on the energy applied. This trauma has minor clinical implications and is avoided by maintaining a minimum safety distance of 1 mm.; (2) According to physics, each plasma is followed by a cavitation bubble. The maximum size of this hubble depends on the energy applied and ranges from 3 mm. (25 mJ) to > 15 mm. (1300 mJ). In proportion to the bubble size, the ureteral wall may be distended or disrupted, even when the probe is not in direct contact with the mucosa. Therefore, the goal should be to obtain a low energy pressure pulse with high disintegration efficacy. Our evaluation of the pressure waves revealed that the selection of a high voltage and a low capacity leads to short and steep ''laser-like'' pulses. These pulses have a significant higher impact on stone disintegration than the broader pulses of the same energy provided by currently available generators.
引用
收藏
页码:849 / 853
页数:5
相关论文
共 20 条
[1]   USE OF A PROTOTYPE-3F ELECTROHYDRAULIC ELECTRODE WITH URETEROSCOPY FOR TREATMENT OF URETERAL CALCULOUS DISEASE [J].
BEGUN, FP ;
JACOBS, SC ;
LAWSON, RK .
JOURNAL OF UROLOGY, 1988, 139 (06) :1188-1191
[2]   ELECTROHYDRAULIC LITHOTRIPSY OF RENAL AND URETERAL CALCULI [J].
DENSTEDT, JD ;
CLAYMAN, RV .
JOURNAL OF UROLOGY, 1990, 143 (01) :13-17
[3]   ELECTROHYDRAULIC LITHOTRIPSY [J].
EATON, JM ;
GLENN, JF ;
MALIN, JM .
JOURNAL OF UROLOGY, 1972, 108 (06) :865-&
[4]   ULTRASONIC AND ELECTROHYDRAULIC LITHOTRIPSY OF URETERAL CALCULI [J].
GOODFRIEND, R .
UROLOGY, 1984, 23 (01) :5-8
[5]  
GREEN DF, 1988, UROL CLIN N AM, V15, P361
[6]  
Ihler B. C., 1992, Laser und Optoelektronik, V24, P76
[7]  
MARBERGER M, 1983, UROL CLIN N AM, V10, P729
[8]  
RANEY AM, 1978, UROLOGY, V7, P284
[9]  
Reuter H J, 1970, J Urol, V104, P834
[10]  
RIEDLINGER RE, 1990, EXTRA INTRAKORPORALE, P4