CIRCUMFERENTIAL PRESSURE AS A RAPID METHOD TO ASSESS INTRAOSSEOUS NEEDLE PLACEMENT

被引:6
作者
STRAUSBAUGH, SD [1 ]
MANLEY, LK [1 ]
HICKEY, RW [1 ]
DIETRICH, AM [1 ]
机构
[1] OHIO STATE UNIV,COLUMBUS,OH 43210
关键词
INTRAOSSEOUS NEEDLE PLACEMENT; CIRCUMFERENTIAL PRESSURE; RESUSCITATION;
D O I
10.1097/00006565-199510000-00002
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
This study was done to determine whether the application of circumferential pressure about an intraosseous (IO) site can be used as a rapid method to detect incorrect placement of an IO needle. We used a prospective, randomized, controlled canine tibial IO model, According to random assignment, 10 needles were placed either intramedullary (correct placement) or extramedullary (incorrect placement) in the anteromedial tibias of 12 euthanized mongrel dogs, Neonatal blood pressure cuffs were placed contiguously above and below the IO needles, One-liter bags of solution were connected to the IO needles via blood tubing. The gravity-dependent rate of flow at each site was measured with and without the blood pressure cuffs inflated to 120 mmHg, Eleven IO needles were correctly placed and 13 were incorrectly placed, Following inflation of the blood pressure cuffs, the mean percent decrease in flow was 48% for the correctly placed IO needles, and 95% for the incorrectly placed IO needles, A two-way repeated measure of analysis of variance was significant between groups (P = 0.006), and a significant interaction was found between groups and flow rates over time (P = 0.033), We conclude that circumferential pressure about an IO infusion site can be used as a rapid method to detect incorrect placement of the IO needle.
引用
收藏
页码:274 / 276
页数:3
相关论文
共 17 条
[11]  
Ribeiro J.A., Price C.T., Knapp D.R., Compartment syndrome of the lower extremity after intraosseous infusion of fluid, J Bone Joint Surg, 75 A, pp. 430-433, (1993)
[12]  
Brunette D.D., Fischer R., Intravenous access in pediatric cardiac arrest, Am J Emerg Med, 6, pp. 577-579, (1988)
[13]  
Rossetti V.A., Thompson B.M., Miller J., Et al., Intraosseous infusion: An alternative route of pediatric intravascular access, Ann Emerg Med, 14, pp. 885-888, (1985)
[14]  
Miner W.F., Cornell H.M., Boite R.G., Et al., Prehospital use of intraosseous infusion by paramedics, Pediatr Emerg Care, 5, pp. 5-7, (1989)
[15]  
Moscati R., Moore G., Compartment syndrome with resultant amputation following intraosseous infusion [letter], Am J Emerg Med, 8, pp. 470-471, (1990)
[16]  
Chameides L., Textbook of Pediatric Advanced Life Support, pp. 43-44, (1990)
[17]  
Glaeser P.W., Hellmich T.R., Szewczuga D., Et al., Five year experience in prehospital intraosseous infusion in children and adults, Ann Emerg Med, 22, pp. 1119-1124, (1993)