LOCALIZATION OF A MISPLACED CORONARY-ARTERY STENT BY MAGNETIC-RESONANCE-IMAGING

被引:13
作者
MOHIADDIN, RH [1 ]
ROBERTS, RH [1 ]
UNDERWOOD, R [1 ]
ROTHMAN, M [1 ]
机构
[1] LONDON CHEST HOSP,DEPT CARDIOL,LONDON E2 9JX,ENGLAND
关键词
MAGNETIC RESONANCE IMAGING; STENT; CORONARY ARTERY;
D O I
10.1002/clc.4960180313
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Coronary artery stents have been developed to overcome arterial abrupt closure and restenosis following balloon angioplasty. Complications of stent insertion include loss of the device from its delivery system into the peripheral circulation. Certain types of stents are almost radiolucent, making localization of the lost devices difficult. Nonferromagnetic metallic biomedical implants induce alteration of the local magnetic field and this leads to loss of signal from the surrounding tissues. We have used this property to localize a misplaced coronary artery stent in a 53-year-old man who underwent unsuccessful stent insertion. A 0.5 Tesla magnetic resonance scanner was used to acquire gradient-echo and spin-echo images. An in vitro experiment was first carried out on a stent similar to that used in our patient to establish that it was nonferromagnetic and to determine the optimum imaging technique. Gradient-echo images with a relatively long echo time (22 ms) gave the largest area of signal loss around the stent, and this sequence was used for localization of the stent found in the patient's left profunda femoris artery. This was subsequently confirmed by digital radiography. We have demonstrated the convenience and practicality of using magnetic resonance imaging for the localization of a misplaced coronary artery stent in a patient. The technique is safe, noninvasive, and uses no ionizing radiation.
引用
收藏
页码:175 / 177
页数:3
相关论文
共 8 条
  • [1] TRANSLUMINAL TREATMENT OF ARTERIOSCLEROTIC OBSTRUCTION - DESCRIPTION OF NEW TECHNIC + PRELIMINARY REPORT OF ITS APPLICATION
    DOTTER, CT
    JUDKINS, MP
    [J]. CIRCULATION, 1964, 30 (05) : 654 - &
  • [2] MAGNETIC-RESONANCE IMAGING OF PROSTHETIC CARDIAC VALVES INVITRO AND INVIVO
    RANDALL, PA
    KOHMAN, LJ
    SCALZETTI, EM
    SZEVERENYI, NM
    PANICEK, DM
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1988, 62 (13) : 973 - 976
  • [3] CLINICAL-EXPERIENCE WITH THE PALMAZ-SCHATZ CORONARY STENT - INITIAL RESULTS OF A MULTICENTER STUDY
    SCHATZ, RA
    BAIM, DS
    LEON, M
    ELLIS, SG
    GOLDBERG, S
    HIRSHFELD, JW
    CLEMAN, MW
    CABIN, HS
    WALKER, C
    STAGG, J
    BUCHBINDER, M
    TEIRSTEIN, PS
    TOPOL, EJ
    SAVAGE, M
    PEREZ, JA
    CURRY, RC
    WHITWORTH, H
    SOUSA, JE
    TIO, F
    ALMAGOR, Y
    PONDER, R
    PENN, IM
    LEONARD, B
    LEVINE, SL
    FISH, RD
    PALMAZ, JC
    [J]. CIRCULATION, 1991, 83 (01) : 148 - 161
  • [4] BALLOON-EXPANDABLE INTRACORONARY STENTS IN THE ADULT DOG
    SCHATZ, RA
    PALMAZ, JC
    TIO, FO
    GARCIA, F
    GARCIA, O
    REUTER, SR
    [J]. CIRCULATION, 1987, 76 (02) : 450 - 457
  • [5] MR IMAGING OF METALLIC IMPLANTS AND MATERIALS - A COMPILATION OF THE LITERATURE
    SHELLOCK, FG
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (04) : 811 - 814
  • [6] HIGH-FIELD-STRENGTH MR IMAGING AND METALLIC BIOMEDICAL IMPLANTS - AN EXVIVO EVALUATION OF DEFLECTION FORCES
    SHELLOCK, FG
    CRUES, JV
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (02) : 389 - 392
  • [7] MAGNETIC-RESONANCE IMAGING OF PROSTHETIC HEART-VALVES
    SOULEN, RL
    BUDINGER, TF
    HIGGINS, CB
    [J]. RADIOLOGY, 1985, 154 (03) : 705 - 707
  • [8] WHITE CJ, 1992, CIRCULATION, V86, P115