THE EFFECTS OF SUPPLY HARMONICS ON THE PERFORMANCE OF COMPACT FLUORESCENT LAMPS

被引:26
作者
ARSENEAU, R [1 ]
OUELLETTE, M [1 ]
机构
[1] NATL RES COUNCIL CANADA,INST RES CONSTRUCT,OTTAWA K1A 0R8,ONTARIO,CANADA
关键词
D O I
10.1109/61.216848
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes a performance evaluation of ten compact fluorescent lighting systems operated with sinusoidal and distorted voltage waveform conditions. The lamps were either provided with an electronic ballast, a magnetic core ballast or a magnetic core ballast with a power factor correction circuit. The test results show that the electrical performance of the compact fluorescent lamps for both sinusoidal and distorted voltage waveform operation is related to the different types of ballast used. The cost of operation of these compact fluorescent lamps was calculated and compared to the cost of a conventional 60 W incandescent lamp.
引用
收藏
页码:473 / 479
页数:7