RADIOIMMUNOASSAY FOR PLASMA HISTAMINE - A STUDY OF FALSE-POSITIVE AND FALSE-NEGATIVE VALUES

被引:29
作者
LAROCHE, D
DUBOIS, F
GERARD, JL
LEFRANCOIS, C
ANDRE, B
VERGNAUD, MC
DUBUS, L
BRICARD, H
机构
[1] CTR HOSP REG UNIV CAEN,DEPT ANAESTHESIOL,F-14033 CAEN,FRANCE
[2] CTR HOSP REG UNIV CAEN,DEPT PNEUMONOL,F-14033 CAEN,FRANCE
关键词
HISTAMINE; MEASUREMENT TECHNIQUES; RADIOIMMUNOASSAY;
D O I
10.1093/bja/74.4.430
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
In order to achieve a correct diagnosis of drug anaphylaxis using a radioimmunoassay devoid of interferences, we have studied factors leading to false positive or false negative values of plasma histamine. Different steps in sample collection were studied systematically in 30 normal volunteers. False positive values were found in haemolysed samples, with histamine concentrations being correlated with haemoglobin concentrations, and where plasma was aspirated from the white-cell layer. There was no significant increase when a tourniquet or vacuum tubes were used, or when blood tubes were left at 4 degrees C overnight. In 12 patients who experienced an anaphylactic reaction, histamine disappeared from blood 10 times more slowly than expected. False negative values were found in two pregnant women and one heparinized patient. Histamine was remarkably stable in vitro in blood or plasma samples, whereas it disappeared rapidly when plasma from a pregnant woman or a heparinized patient was added to the sample. We conclude that false positive and false negative values are rare when using this radioimmunoassay.
引用
收藏
页码:430 / 437
页数:8
相关论文
共 29 条
  • [1] ADRIANI E, 1988, ALLERGY S7, V43, P88
  • [2] AHLMARK A, 1944, ACTA PHYSL SCAND S28, V9, P60
  • [3] RESPONSE OF PLASMA HISTAMINASE ACTIVITY TO SMALL DOSES OF HEPARIN IN NORMAL SUBJECTS AND PATIENTS WITH HYPERLIPOPROTEINEMIA
    BAYLIN, SB
    BEAVEN, MA
    KRAUSS, RM
    KEISER, HR
    [J]. JOURNAL OF CLINICAL INVESTIGATION, 1973, 52 (08) : 1985 - 1993
  • [4] ANAPHYLAXIS
    BOCHNER, BS
    LICHTENSTEIN, LM
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (25) : 1785 - 1790
  • [5] CASTELLS M, 1987, J IMMUNOL, V138, P2814
  • [6] RAPID METHOD FOR ESTIMATION OF PLASMA HAEMOGLOBIN LEVELS
    CRIPPS, CM
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 1968, 21 (01) : 110 - &
  • [7] MEASUREMENT OF PLASMA HISTAMINE - DESCRIPTION OF AN IMPROVED METHOD AND NORMAL VALUES
    DYER, J
    WARREN, K
    MERLIN, S
    METCALFE, DD
    KALINER, M
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1982, 70 (02) : 82 - 87
  • [8] A NEW RADIOIMMUNOASSAY FOR HUMAN MAST-CELL TRYPTASE USING MONOCLONAL-ANTIBODIES
    ENANDER, I
    MATSSON, P
    NYSTRAND, J
    ANDERSSON, AS
    EKLUND, E
    BRADFORD, TR
    SCHWARTZ, LB
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1991, 138 (01) : 39 - 46
  • [9] MEASUREMENT OF HISTAMINE - A QUALITY-CONTROL STUDY
    GLEICH, GJ
    HULL, WM
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1980, 66 (04) : 295 - 298
  • [10] HANSSON R, 1966, ACTA MED SCAND, V180, P533