3-DIMENSIONAL RECONSTRUCTION OF BOVINE INTRADURAL SPINAL ROOT MYELIN BY ELECTRON-MICROSCOPE TOMOGRAPHY

被引:2
|
作者
SEDZIK, J
OFVERSTEDT, LG
SKOGLUND, U
机构
[1] UNIV UPPSALA,CTR BIOMED,DEPT BIOCHEM,S-75105 UPPSALA,SWEDEN
[2] KAROLINSKA INST,MED NOBEL INST,DEPT MOLEC GENET,S-10401 STOCKHOLM 60,SWEDEN
关键词
NERVOUS SYSTEM; IMAGE ANALYSIS; HEAVY METAL STAINING;
D O I
10.1002/jnr.490310222
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Electron microscope tomography was used to reconstruct three-dimensionally the configuration of heavy metal staining in bovine intradural spinal root myelin. Samples were fixed with glutaraldehyde, exposed to osmium tetroxide, embedded, thin sectioned, and finally stained with uranyl-acetate and lead citrate. Reconstructions up to 4.2 nm resolution showed a non-uniform distribution of stain in the planes of individual cytoplasmic appositions (major dense lines). In each reconstructed major dense line the stain was distributed in striated, well-defined structures. Those structures appear to be nearly parallel between neighboring major dense lines. The distribution of stain in the Schmidt-Lanterman cleft did not resemble the distribution of stain in the major dense line; however, weak striations were present. Evidence that the striated structures are not an artifact due to image calculation is discussed.
引用
收藏
页码:387 / 393
页数:7
相关论文
共 50 条
  • [1] 3-DIMENSIONAL OBSERVATION BY ELECTRON-MICROSCOPE
    ISHIDA, Y
    JOURNAL OF ELECTRON MICROSCOPY, 1990, 39 (04): : 285 - 285
  • [2] SUGGESTION FOR 3-DIMENSIONAL STILLS WITH TRANSMISSION SCANNING ELECTRON-MICROSCOPE
    TYPKE, D
    HOPPE, W
    BURGER, M
    LEFRANC, G
    DIETRICH, I
    MIKROSKOPIE, 1980, 36 (9-10) : 303 - 303
  • [3] 3-DIMENSIONAL MODELING OF VARIOUS ASPECTS OF THE SCANNING ELECTRON-MICROSCOPE
    ROUSE, J
    MUNRO, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 298 (1-3): : 78 - 84
  • [4] 3-DIMENSIONAL STRUCTURE OF A SPECIFIC PRE-MESSENGER RNP PARTICLE ESTABLISHED BY ELECTRON-MICROSCOPE TOMOGRAPHY
    SKOGLUND, U
    ANDERSSON, K
    STRANDBERG, B
    DANEHOLT, B
    NATURE, 1986, 319 (6054) : 560 - 564
  • [5] 3-DIMENSIONAL RECONSTRUCTION OF ELECTRON-MICROSCOPE OBJECTS CHARACTERIZED BY LINEAR ELEMENTS, APPLIED TO CDO BENT WHISKERS
    SIMOV, S
    SIMOVA, E
    PIROV, J
    JOURNAL OF MATERIALS SCIENCE LETTERS, 1987, 6 (02) : 235 - 237
  • [6] 3-DIMENSIONAL MEASUREMENTS OF LSI MICROSTRUCTURES BY SCANNING ELECTRON-MICROSCOPE STEREOSCOPY
    TAKASE, T
    NAKAMAE, K
    FUJIOKA, H
    URA, K
    JOURNAL OF ELECTRON MICROSCOPY, 1989, 38 (04): : 301 - 301
  • [7] 3-DIMENSIONAL RECONSTRUCTION OF TUBULAR MYELIN
    YOUNG, SL
    FRAM, EK
    LARSON, EW
    EXPERIMENTAL LUNG RESEARCH, 1992, 18 (04) : 497 - 504
  • [8] 3-DIMENSIONAL MEASUREMENT OF ELECTRON-MICROSCOPE STEREOGRAMS OBTAINED BY BLODORN AND LANGE METHOD
    BURKHARDT, R
    OPTIK, 1978, 50 (04): : 279 - 296
  • [9] SUBMICRON 3-DIMENSIONAL STRUCTURE OBSERVATION BY CYCLOTRON SEM(SCANNING ELECTRON-MICROSCOPE)
    NOMURA, N
    KOIZUMI, T
    HARAFUJI, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1991, 30 (11B): : 3282 - 3286
  • [10] ENERGY-FILTERING AND EXIT SURFACE WAVE-FRONT RECONSTRUCTION OF THICK BIOLOGICAL SPECIMENS - TECHNICAL DEVELOPMENT FOR 3-DIMENSIONAL ELECTRON-MICROSCOPE TOMOGRAPHY
    HAN, KF
    SEDAT, JW
    AGARD, DA
    ZOOLOGICAL STUDIES, 1995, 34 : 139 - 141