ELECTROMAGNETIC ACOUSTIC NOISE OF CONVERTER-FED PERMANENT-FIELD SYNCHRONOUS MOTORS .2. THE INFLUENCE OF THE CONVERTER SUPPLY ON THE NOISE OF A 1.1-MW MOTOR

被引:4
作者
TAEGEN, F [1 ]
KOLBE, J [1 ]
OSTERLOH, H [1 ]
机构
[1] WEHRTECH DIENSTSTELLE SCHIFFE & MARINEWAFFEN,W-2330 ECKERNFORDE,GERMANY
来源
ARCHIV FUR ELEKTROTECHNIK | 1991年 / 74卷 / 05期
关键词
D O I
10.1007/BF01574122
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to get a basic insight into the generation of the acoustic noise due to converter supply, the orders and frequencies of the force waves as well as the causing current harmonics are determined under the assumption of a periodical and phase balanced supply. Measurements of the airborne and structure-borne noise are performed on a 1.1 MW motor. They also exhibit the most important natural frequency of the stator construction. The comparison of the experiments with the calculations according to part 1 elucidates the different influences of the converter supply.