COMPARISON OF DIRECT AND INDIRECT BLOOD-PRESSURE MEASUREMENT IN ANESTHETIZED DOGS

被引:0
作者
SAWYER, DC
BROWN, M
STRILER, EL
DURHAM, RA
LANGHAM, MA
RECH, RH
机构
[1] MICHIGAN STATE UNIV,COLL VET MED,DEPT PHARMACOL & TOXICOL,E LANSING,MI 48824
[2] UNIV ILLINOIS,BIOL RESOURCES LAB,CHICAGO,IL 60612
来源
LABORATORY ANIMAL SCIENCE | 1991年 / 41卷 / 02期
关键词
D O I
暂无
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
This study was conducted to determine whether blood pressures and pulse rate could be determined accurately by indirect measurements from the front and hind legs of 15- to 40-kg dogs anesthetized with isoflurane. Indirect measurements from each animal were compared to direct measurements obtained from a catheter placed into the abdominal aorta via the femoral artery at four ranges of systolic pressure. When systolic pressure was above 80 mm Hg, indirect measurements were either the same as direct measurements or slightly lower. However, when systolic pressures were below 80 mm Hg, indirect systolic pressure measurements were 6 to 15% higher than direct measurements. Larger differences in diastolic pressures were found, which resulted in differences in mean pressure. The most accurate measurements were found when the cuff width-to-limb circumference ratio was between 0.4 and 0.6 and when systolic pressure was between 80 and 100 mm Hg.
引用
收藏
页码:134 / 138
页数:5
相关论文
共 12 条
[1]  
COULTER DB, 1981, CORNELL VET, V71, P76
[2]   DIRECT BLOOD-PRESSURE MEASUREMENT - DYNAMIC-RESPONSE REQUIREMENTS [J].
GARDNER, RM .
ANESTHESIOLOGY, 1981, 54 (03) :227-236
[3]  
GARNER HE, 1975, LAB ANIM SCI, V25, P197
[4]   INDIRECT MEAN ARTERIAL-PRESSURE IN THE ANESTHETIZED DOG [J].
GEDDES, LA ;
COMBS, W ;
DENTON, W ;
WHISTLER, SJ ;
BOURLAND, JD .
AMERICAN JOURNAL OF PHYSIOLOGY, 1980, 238 (05) :H664-H666
[5]  
GIBBS NC, 1988, HEART LUNG, V17, P43
[6]  
HARVEY J, 1983, LAB ANIM SCI, V33, P370
[7]   IDENTIFICATION AND EVALUATION OF NON-INVASIVE BLOOD-PRESSURE MEASURING TECHNIQUES [J].
HASSLER, CR ;
LUTZ, GA ;
LINEBAUGH, R ;
CUMMINGS, KD .
TOXICOLOGY AND APPLIED PHARMACOLOGY, 1979, 47 (02) :193-201
[8]   DIRECT AND INDIRECT BLOOD-PRESSURE MEASUREMENTS IN BABOONS [J].
MCMAHAN, CA ;
WIGODSKY, HS ;
MOORE, GT .
JOURNAL OF APPLIED PHYSIOLOGY, 1976, 41 (05) :806-809
[9]   NONINVASIVE MEASUREMENT OF SYSTEMIC ARTERIAL BLOOD-PRESSURE IN THE CONSCIOUS BEAGLE DOG [J].
PETTERSEN, JC ;
LINARTZ, RR ;
HAMLIN, RL ;
STOLL, RE .
FUNDAMENTAL AND APPLIED TOXICOLOGY, 1988, 10 (01) :89-97
[10]  
ROBINSON EP, 1986, AM J VET RES, V10, P2105