A flow-injection system is used for monitoring and control of a biological waste-water treatment plant with biological removal of phosphate and nitrate. The waste-water treatment plant is an activated sludge type on a pilot scale, with municipal waste water as the influent. The flow-injection system monitors the concentrations of phosphate, ammonia and nitrate in four places: in the inlet, in the outlet of the anaerobic pretreatment tank, in one of the aeration tanks and in the outlet of the plant. Sampling is carried out via a cross-flow filter system, based on an ultra-filtration membrane. The analysers employ highly pulsating, single-piston liquid chromatographic pumps. Synchronization of injection time and pump pulses eliminates the need for pulse-damping devices and ensures high reproducibility. The chemical methods are based on classical colorimetric methods. The measurement system has been designed with emphasis on long-term stability, low reagent consumption and minimum maintenance. To maintain stable, low flow-rates, on-line degassing has been installed for each reagent. Further, on-line standard calibration is being used to compensate for drift in the sensitivity of the analysers. The system is controlled by a PC, programmed in ASYST. The calibrated data is fed to a programmable logic controller (PLC), which also controls the pilot plant. A supervisory PC, programmed in Factory Link, stores and presents data. The measurements will be used for studies of different control strategies for the plant, e.g., rule-based control. © 1990.
引用
收藏
页码:191 / 199
页数:9
相关论文
共 9 条
[1]   BIOLOGICAL REMOVAL OF PHOSPHORUS FROM WASTE-WATER [J].
ARVIN, E .
CRC CRITICAL REVIEWS IN ENVIRONMENTAL CONTROL, 1985, 15 (01) :25-64
[2]   MERGING ZONES IN FLOW INJECTION ANALYSIS .1. DOUBLE PROPORTIONAL INJECTOR AND REAGENT CONSUMPTION [J].
BERGAMIN, H ;
ZAGATTO, EAG ;
KRUG, FJ ;
REIS, BF .
ANALYTICA CHIMICA ACTA, 1978, 101 (01) :17-23
[3]   SIMULTANEOUS DETERMINATION OF NITRATE AND NITRITE BY FLOW-INJECTION ANALYSIS [J].
GINE, MF ;
BERGAMIN, H ;
ZAGATTO, EAG ;
REIS, BF .
ANALYTICA CHIMICA ACTA, 1980, 114 (FEB) :191-197
[4]  
PEDERSEN KM, 1988, THESIS TU DENMARK
[5]  
PEDERSEN KM, 1990, INT ASS WATER POLLUT
[6]  
PEDERSEN KM, 1985, 1ST P IFAC S NORDW, P131
[7]  
Ruzicka J., 1988, FLOW INJECTION ANAL, Vsecond
[8]  
THORNBERG DE, 1987, WAT SUPPLY, V6, P361
[9]   MEMBRANE SEPARATION IN FLOW-INJECTION ANALYSIS - GAS-DIFFUSION [J].
VANDERLINDEN, WE .
ANALYTICA CHIMICA ACTA, 1983, 151 (02) :359-369