BIOCOMPATIBILITY OF POLYETHYLENE AND HOST RESPONSE TO LOOSENING OF CEMENTLESS TOTAL HIP-REPLACEMENT

被引:0
作者
SANTAVIRTA, S
NORDSTROM, D
METSARINNE, K
KONTTINEN, YT
机构
[1] UNIV HELSINKI, CENT HOSP, DEPT MED 4, SF-00170 HELSINKI 17, FINLAND
[2] UNIV HELSINKI, DEPT ANAT, SF-00170 HELSINKI 17, FINLAND
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A human lymphocyte culture protocol was used to identify the biocompatibility pattern of fine particulate ultra-high molecular weight polyethylene. Polyethylene did not cause an increase in lymphocyte DNA synthesis as assessed by the H-3-thymidine incorporation method on culture Days 1, 3, nor 5. As analyzed with monoclonal activation markers, the polyethylene dependent expression of major histocompatibility complex (MHC) class II antigen as well as interleukin-2 receptor (CD25) was virtually nonexistent. An apparent increase in the amount of CD11b positive monocytes/macrophages from 7% +/- 2% to 22% +/- 6% was recorded. Samples of pseudocapsules of the totally replaced hips (THR) obtained at revision operations for aseptic loosening of cementless prostheses with polyethylene lining of the acetabular component, were obtained from ten patients for immunopathologic studies. In seven cases the prostheses consisted of chromium-cobalt-molybdenum steel alloy and in three cases of titanium. Revisions were performed on average 4.6 years (range, 2.5-7) after insertion of the prostheses. The predominant cell in the lining cell layer of the periprosthetic cavity was in each case the CD11b, CD68, and nonspecific esterase positive but endogenous peroxidase-negative macrophage. Proline 4-hydroxylase positive fibroblasts dominated the stroma that was also inhabited by usually perivascular mononuclear cell infiltrations of mainly CD11b/CD68 phenotype with occasional CD4-positive cells. Only few mononuclear cells were activated CD25 positive T cells or CD19-positive B-lymphocytes. In titanium-based THRs, the cytoplasm of the macrophages contained a large number of small metallic particles, although this phenomenon was not seen in chromium-cobalt-molybdenum steel-based THRs. Fine particulate ultra-high molecular weight polyethylene is immunologically relatively inert. Nevertheless, it causes a clear foreign body type of phenomenon in vitro. The loosening of cementless acetabular components was associated with CD11b- and CD68-positive macrophage reaction in the pseudocapsular tissue. In any case, there is no clinical or experimental evidence to suggest that the use of cementless THR prostheses with polyethylene sockets would prevent an adverse biologic host response.
引用
收藏
页码:100 / 110
页数:11
相关论文
共 39 条
[1]   METALLIC WEAR IN FAILED TITANIUM-ALLOY TOTAL HIP REPLACEMENTS - A HISTOLOGICAL AND QUANTITATIVE-ANALYSIS [J].
AGINS, HJ ;
ALCOCK, NW ;
BANSAL, M ;
SALVATI, EA ;
WILSON, PD ;
PELLICCI, PM ;
BULLOUGH, PG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :347-356
[2]   CEMENTLESS REVISION OF AGGRESSIVE GRANULOMATOUS LESIONS IN HIP REPLACEMENTS [J].
ESKOLA, A ;
SANTAVIRTA, S ;
KONTTINEN, YT ;
HOIKKA, V ;
TALLROTH, K ;
LINDHOLM, TS .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (02) :212-216
[3]   POLYETHYLENE WEAR IN KNEE ARTHROPLASTY - A REVIEW [J].
GOODMAN, S ;
LIDGREN, L .
ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (03) :358-364
[4]   THE EFFECTS OF BULK VERSUS PARTICULATE TITANIUM AND COBALT CHROME ALLOY IMPLANTED INTO THE RABBIT TIBIA [J].
GOODMAN, SB ;
FORNASIER, VL ;
LEE, J ;
KEI, J .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1990, 24 (11) :1539-1549
[5]  
GOODMAN SB, 1988, J ARTHROPLASTY, V3, P541
[6]   USE OF AVIDIN-BIOTIN-PEROXIDASE COMPLEX (ABC) IN IMMUNOPEROXIDASE TECHNIQUES - A COMPARISON BETWEEN ABC AND UNLABELED ANTIBODY (PAP) PROCEDURES [J].
HSU, SM ;
RAINE, L ;
FANGER, H .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1981, 29 (04) :577-580
[7]   HISTOMORPHOLOGICAL STUDIES OF THE LONG-TERM SKELETAL RESPONSES TO WELL FIXED CEMENTED FEMORAL COMPONENTS [J].
JASTY, M ;
MALONEY, WJ ;
BRAGDON, CR ;
HAIRE, T ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (08) :1220-1229
[8]   LOCALIZED OSTEOLYSIS IN STABLE, NONSEPTIC TOTAL HIP-REPLACEMENT [J].
JASTY, MJ ;
FLOYD, WE ;
SCHILLER, AL ;
GOLDRING, SR ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (06) :912-919
[9]  
Konttinen Y T, 1988, Scand J Rheumatol Suppl, V76, P95
[10]   AN IMMUNOPEROXIDASE-AUTORADIOGRAPHY DOUBLE LABELING METHOD FOR ANALYSIS OF LYMPHOCYTE-ACTIVATION MARKERS AND DNA-SYNTHESIS [J].
KONTTINEN, YT ;
SEGERBERGKONTTINEN, M ;
NORDSTROM, D ;
BERGROTH, V ;
SCHEININ, T ;
SAARI, H .
JOURNAL OF IMMUNOLOGICAL METHODS, 1988, 110 (01) :19-27