CHEMOMETRIC TECHNIQUES IN ELECTROCHEMISTRY - A CRITICAL-REVIEW

被引:104
作者
BROWN, SD
BEAR, RS
机构
[1] Department of Chemistry and Biochemistry, University of Delaware, Newark
[2] Department of Chemistry, University of Houston, Houston, TX
关键词
CHEMOMETRICS; ELECTROCHEMISTRY; DATA ANALYSIS; PARAMETER ESTIMATION; PATTERN RECOGNITION; CALIBRATION;
D O I
10.1080/10408349308048820
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
With the ever-increasing power and low prices of modern laboratory microcomputers it is becoming common for the average researcher to routinely employ sophisticated data analysis methods. Most of these methods have been the subject of study by researchers associated with the discipline of analytical chemistry known as chemometrics. Although the application of chemometrics has become routine in all fields of analytical chemistry, this article is focused on those applications appearing in electroanalytical chemistry. Examples of chemometric solutions to a variety of electrochemical problems are reviewed in conjunction with brief presentations of the relevant chemometric background.
引用
收藏
页码:99 / 131
页数:33
相关论文
共 106 条
[1]   DETERMINATION OF ELECTROCHEMICAL KINETIC-PARAMETERS USING THE BOND-HENDERSON-OLDHAM GLOBAL ANALYSIS [J].
ANDERSON, MR ;
EVANS, DH .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 230 (1-2) :273-280
[2]  
[Anonymous], 1965, FOURIER TRANSFORM IT
[3]  
[Anonymous], 1986, NUMERICAL RECIPES
[4]   REGRESSION-ANALYSIS OF ELECTROCHEMICAL DATA WITH EXPANDING SPACE GRID DIGITAL-SIMULATION AT SPHERICAL ELECTRODES [J].
ARENA, JV ;
RUSLING, JF .
ANALYTICAL CHEMISTRY, 1986, 58 (07) :1481-1488
[5]   FOURIER SMOOTHING OF ELECTROCHEMICAL DATA WITHOUT THE FAST FOURIER-TRANSFORM [J].
AUBANEL, EE ;
MYLAND, JC ;
OLDHAM, KB ;
ZOSKI, CG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 184 (02) :239-255
[6]   ASYMMETRIC DOUBLE POTENTIAL STEP CHRONOABSORPTOMETRIC DETERMINATION OF HETEROGENEOUS ELECTRON-TRANSFER KINETIC-PARAMETERS [J].
BANCROFT, EE ;
BLOUNT, HN .
ANALYTICAL CHEMISTRY, 1986, 58 (14) :2944-2949
[7]   DECONVOLUTION OF VOLTAMMETRIC MEASUREMENTS FROM THE SLOW RESPONSE OF CURRENT TRANSDUCERS [J].
BARANSKI, AS ;
LU, W .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 260 (01) :1-13
[8]   THE EXTRACTION OF HETEROGENEOUS KINETIC-PARAMETERS FROM COMBINED CHRONOAMPEROMETRIC AND CHRONOCOULOMETRIC DATA BY A MULTIPLE-REGRESSION PROCEDURE [J].
BARBERO, C ;
ZON, MA ;
FERNANDEZ, H .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 265 (1-2) :23-37
[9]   KALMAN FILTER-OPTIMIZED SIMULATION FOR STEP VOLTAMMETRY [J].
BEAR, RS ;
BROWN, SD .
ANALYTICAL CHEMISTRY, 1993, 65 (08) :1061-1068
[10]   SPARINGLY SELECTIVE ION-SELECTIVE ELECTRODE ARRAYS FOR MULTICOMPONENT ANALYSIS [J].
BEEBE, K ;
UERZ, D ;
SANDIFER, J ;
KOWALSKI, B .
ANALYTICAL CHEMISTRY, 1988, 60 (01) :66-71