ANODIC-STRIPPING VOLTAMMETRY OF SELENIUM(IV) AT A GOLD FIBER WORKING ELECTRODE

被引:26
作者
MCLAUGHLIN, K [1 ]
BOYD, D [1 ]
HUA, C [1 ]
SMYTH, MR [1 ]
机构
[1] DUBLIN CITY UNIV,SCH CHEM SCI,DUBLIN 9,IRELAND
关键词
SELENIUM; STRIPPING VOLTAMMETRY; GOLD FIBER ELECTRODE;
D O I
10.1002/elan.1140040704
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The anodic stripping voltammetry of selenium (IV) in a gold fiber electrochemical flow cell is described. The cell is simple to construct and flexible in its operation. The nonlinear diffusional mass transport characteristics of such small diameter electrodes influence the anodic stripping voltammetry of Se(IV) with the result that significant deposition of metal ions occurs during the scan period from the deposition potential to the peak potential. Therefore, an extremely short deposition period of the order of 20 seconds can be employed at the gold fiber electrode. The system described resulted in a linear working range from 0-15 ng/mL, a detection limit of 0.5 ng/mL Se(IV) and a relative standard deviation of 6% at 5 ng/mL (n = 7) in pure solution.
引用
收藏
页码:689 / 693
页数:5
相关论文
共 14 条
[1]   STRIPPING VOLTAMMETRIC DETERMINATION OF SELENIUM IN BIOLOGICAL-MATERIALS BY DIRECT CALIBRATION [J].
ADELOJU, SB ;
BOND, AM ;
BRIGGS, MH ;
HUGHES, HC .
ANALYTICAL CHEMISTRY, 1983, 55 (13) :2076-2082
[2]   VOLTAMMETRIC DEPOSITION AND STRIPPING OF SELENIUM(IV) AT A ROTATING GOLD-DISK ELECTRODE IN 0.1M PERCHLORIC-ACID [J].
ANDREWS, RW ;
JOHNSON, DC .
ANALYTICAL CHEMISTRY, 1975, 47 (02) :294-299
[4]  
BROGHAMER WL, 1976, CANCER, V37, P1384, DOI 10.1002/1097-0142(197603)37:3<1384::AID-CNCR2820370319>3.0.CO
[5]  
2-E
[6]   DEVELOPMENT OF A MICRO-ELECTROCHEMICAL FLOW CELL USING CARBON OR GOLD FIBERS FOR VOLTAMMETRIC AND AMPEROMETRIC ANALYSES [J].
HUA, C ;
SAGAR, KA ;
MCLAUGHLIN, K ;
JORGE, M ;
MEANEY, MP ;
SMYTH, MR .
ANALYST, 1991, 116 (11) :1117-1120
[7]   AUTOMATED-DETERMINATION OF TOTAL ARSENIC IN SEA-WATER BY FLOW CONSTANT-CURRENT STRIPPING ANALYSIS WITH GOLD FIBER ELECTRODES [J].
HUA, C ;
JAGNER, D ;
RENMAN, L .
ANALYTICA CHIMICA ACTA, 1987, 201 :263-268
[8]   DETERMINATION OF SELENIUM BY MEANS OF COMPUTERIZED FLOW CONSTANT-CURRENT STRIPPING AT CARBON-FIBER ELECTRODES - APPLICATION TO HUMAN WHOLE-BLOOD AND MILK POWDER [J].
HUA, C ;
JAGNER, D ;
RENMAN, L .
ANALYTICA CHIMICA ACTA, 1987, 197 :257-264
[9]   SELENIUM LEVELS IN HUMAN-BLOOD AND TISSUES IN HEALTH AND IN DISEASE [J].
MCCONNELL, KP ;
BROGHAMER, WL ;
BLOTCKY, AJ ;
HURT, OJ .
JOURNAL OF NUTRITION, 1975, 105 (08) :1026-1031
[10]   DETERMINATION OF SELENIUM IN BLOOD-PLASMA AND SERUM BY FLOW-INJECTION HYDRIDE GENERATION ATOMIC-ABSORPTION SPECTROMETRY [J].
MCLAUGHLIN, K ;
DADGAR, D ;
SMYTH, MR ;
MCMASTER, D .
ANALYST, 1990, 115 (03) :275-278