Role of the O-arm and Computer-assisted Navigation of Safe Screw Fixation in Children with Traumatic Rotatory Atlantoaxial Subluxation

被引:9
作者
Attia, Walid [1 ]
Orief, Tamer [1 ]
Almusrea, Khaled [1 ]
Alfawareh, Mohamed [1 ]
Soualmi, Lahbib [1 ]
Orz, Yasser [1 ]
机构
[1] Natl Neurosci Inst, King Fahad Med City, Dept Spine Surg, MBN 020007,POB 59046, Riyadh 11525, Saudi Arabia
关键词
Atlantoaxial joint fusion; Intraoperative computer-assisted 3D navigation; Computer-assisted three-dimensional imaging;
D O I
10.4184/asj.2012.6.4.266
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Study Design: A retrospective analysis of 7 patients with traumatic rotatory atlanto-axial subluxation. Overview of Literature: Cases of traumatic rotatory atlantoaxial subluxation in children are difficult to be stabilized. Surgical challenges include: narrow pedicles, medial vertebral arteries, vertebral artery anomalies, fractured pedicles or lateral masses, and fixed subluxation. The use of O-arm and computer-assisted navigation are still tested as aiding tools in such operative modalities. Purpose: Report of clinical series for evaluation of the safety of use of the O-arm and computed assisted-navigation in screw fixation in children with traumatic rotatory atlantoaxial subluxation. Methods: In the present study, 7 cases of rotatory atlantoaxial traumatic subluxation were operated between December 2009 and March 2011. All patient-cases had undergone open reduction and instrumentation using atlas lateral mass and axis pedicle screws with intraoperative O-arm with computer-assisted navigation. Results: All hardware was safely placed in the planned trajectories in all the 7 cases. Intraoperative O-arm and computer assisted-navigation were useful in securing neural and vascular tissues safety with tough-bony purchases of the hardware from the first and only trial of application with sufficient reduction of the subluxation. Conclusions: Successful surgery is possible with using the intraoperative O-arm and computer-assisted navigation in safe and proper placement of difficult atlas lateral mass and axis pedicle screws for rotatory atlantoaxial subluxation in children.
引用
收藏
页码:266 / 273
页数:8
相关论文
共 19 条
[1]  
[Anonymous], 1984, Pediatrics, V74, P152
[2]   Effect of frameless stereotaxy on the accuracy of C1-2 transarticular screw placement [J].
Bloch, O ;
Holly, LT ;
Park, J ;
Obasi, C ;
Kim, K ;
Johnson, JP .
JOURNAL OF NEUROSURGERY, 2001, 95 (01) :74-79
[3]   ATLANTO-AXIAL ARTHRODESIS BY WEDGE COMPRESSION METHOD [J].
BROOKS, AL ;
JENKINS, EB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (03) :279-284
[4]   CHRONIC ATLANTOAXIAL ROTATORY FIXATION CORRECTION BY CERVICAL TRACTION, MANIPULATION, AND BRACING [J].
BURKUS, JK ;
DEPONTE, RJ .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1986, 6 (05) :631-635
[5]   SPINE FUSION FOR ATLANTO-AXIAL INSTABILITY [J].
FIELDING, JW ;
HAWKINS, RJ ;
RATZAN, SA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (03) :400-407
[6]  
Gallie WE., 1939, AM J SURG, V46, P495, DOI DOI 10.1016/S0002-9610(39)90309-0
[7]   Atlantoaxial transarticular screw fixation: a review of surgical indications, fusion rate, complications, and lessons learned in 67 pediatric patients [J].
Gluf, WM ;
Brockmeyer, DL .
JOURNAL OF NEUROSURGERY-SPINE, 2005, 2 (02) :164-169
[8]   Posterior C1-C2 fusion with polyaxial screw and rod fixation [J].
Harms, J ;
Melcher, RP .
SPINE, 2001, 26 (22) :2467-2471
[9]   POSTERIOR STABILIZATION WITH AN INTERLAMINAR CLAMP IN CERVICAL INJURIES - TECHNICAL NOTE AND REVIEW OF THE LONG-TERM EXPERIENCE WITH THE METHOD [J].
HOLNESS, RO ;
HUESTIS, WS ;
HOWES, WJ ;
LANGILLE, RA .
NEUROSURGERY, 1984, 14 (03) :318-322
[10]   Intraoperative, full-rotation, three-dimensional image (O-arm)-based navigation system for cervical pedicle screw insertion [J].
Ishikawa, Yoshimoto ;
Kanemura, Tokumi ;
Yoshida, Go ;
Matsumoto, Akiyuki ;
Ito, Zenya ;
Tauchi, Ryoji ;
Muramoto, Akio ;
Ohno, Shuichiro ;
Nishimura, Yusuke .
JOURNAL OF NEUROSURGERY-SPINE, 2011, 15 (05) :472-478