LARGE-TIP-ANGLE SPIN-ECHO IMAGING - THEORY AND APPLICATIONS

被引:10
作者
ELSTER, AD
PROVOST, TJ
机构
[1] Department of Radiology, Bowman Gray School of Medicine, Wake Forest University, Medical Center Boulevard, Winston-Salem, NC
关键词
MAGNETIC RESONANCE; PULSE SEQUENCES; MR; TISSUE CHARACTERIZATION; COMPARATIVE STUDIES; PHYSICS; RAPID IMAGING; TECHNOLOGY;
D O I
10.1097/00004424-199310000-00017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. Tissue contrast phenomenology was investigated analytically and clinically for a class of magnetic resonance (MR) pulse sequences we call large-tip-angle (LTA) spin-echo (SE) imaging. In comparison to traditional SE sequences (denoted 90-degrees-180-degrees-echo), the LTA sequence is of the form alpha-degrees-180-degrees-echo, where 90-degrees < alpha < 180-degrees. Theoretical analysis shows that appropriately designed LTA sequences can selectively boost the MR signal by 10%-150% in substances whose spin lattice (T1) relaxation values equal or exceed the sequence repetition time (TR). This unique contrast behavior potentially allows one to reduce TR (and hence imaging time) by 30% to 50% while maintaining constant T2-weighted contrast or contrast-to-noise within an image. METHODS. Preliminary clinical testing of LTA sequences was performed in 60 patients with a wide range of cranial, spinal, musculoskeletal, and abdominal pathologies. Large-tip-angle images (1,500/80/130-degrees) were blindly and prospectively compared to conventional (2,600/80/90-degrees) SE images. RESULTS. Principal diagnoses were concordant between the readers in all cases, although minor variances in detail features were noted in 6 (10%) of 60 cases. Large-tip-angle sequences revealed small cystic areas in two cerebral neoplasms and in a herniated disk which were not apparent on the standard SE images. However, the LTA images were rated to be ''noisier'' by visual assessment in 43 of 60 cases, the exception being for abdominal examinations, where respiratory and peristaltic artifacts were judged more severe on the standard SE sequences. CONCLUSIONS. Large-tip-angle SE imaging is an interesting technique capable of improving image contrast and signal from lesions with long T1 values when the sequence repetition time (TR) is short.
引用
收藏
页码:944 / 953
页数:10
相关论文
共 16 条
  • [1] RF MAGNETIC-FIELD PENETRATION, PHASE-SHIFT AND POWER DISSIPATION IN BIOLOGICAL TISSUE - IMPLICATIONS FOR NMR IMAGING
    BOTTOMLEY, PA
    ANDREW, ER
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1978, 23 (04) : 630 - 643
  • [2] CONTRAST IN RAPID MR IMAGING - T1-WEIGHTED AND T2-WEIGHTED IMAGING
    BUXTON, RB
    EDELMAN, RR
    ROSEN, BR
    WISMER, GL
    BRADY, TJ
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (01) : 7 - 16
  • [3] CLINICAL UTILITY OF PARTIAL FLIP ANGLE T2-WEIGHTED SPIN-ECHO IMAGING OF THE BRAIN
    CHANG, KH
    YI, JG
    HAN, MH
    CHO, MH
    HAN, MC
    CHO, ZH
    KIM, CW
    [J]. NEURORADIOLOGY, 1990, 32 (04) : 255 - 260
  • [4] CHISIN R, 1989, AM J NEURORADIOL, V10, P719
  • [5] ELSTER AD, 1993, RADIOLOGY, V186, P1
  • [6] ELSTER AD, 1986, MAGNETIC RESONANCE I, P34
  • [7] APPLICATION OF FOURIER TRANSFORM SPECTROSCOPY TO MAGNETIC RESONANCE
    ERNST, RR
    ANDERSON, WA
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1966, 37 (01) : 93 - +
  • [8] FEIGLIN DH, 1991, J MAGN RESON IMAGING, V1, P235
  • [9] Jones J P, 1985, Magn Reson Annu, P71
  • [10] PARTIAL FLIP ANGLE MR IMAGING
    MILLS, TC
    ORTENDAHL, DA
    HYLTON, NM
    CROOKS, LE
    CARLSON, JW
    KAUFMAN, L
    [J]. RADIOLOGY, 1987, 162 (02) : 531 - 539