THE ELECTROCHEMISTRY OF HYDROGEN-PEROXIDE ON EVAPORATED GOLD/PALLADIUM COMPOSITE ELECTRODES - MANUFACTURE AND ELECTROCHEMICAL CHARACTERIZATION

被引:42
作者
JOHNSTON, DA
CARDOSI, MF
VAUGHAN, DH
机构
[1] UNIV PAISLEY,DEPT SCI BIOL,SENSORS GRP,PAISLEY PA1 2BE,RENFREW,SCOTLAND
[2] UNIV PAISLEY,DEPT CHEM & CHEM ENGN,SENSORS GRP,PAISLEY PA1 2BE,RENFREW,SCOTLAND
关键词
HYDROGEN PEROXIDE; PALLADIUM; THIN-FILM; ELECTROCATALYSIS; SENSORS;
D O I
10.1002/elan.1140070603
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A thin-film composite metal electrode is described for the amperometric measurement of hydrogen peroxide. By thermally evaporating a 27 mu m layer of gold/palladium through a copper mask onto a plastic substrate a number of chemically equivalent sensing elements can be prepared. On these electrodes, hydrogen peroxide can be oxidized at a voltage of 0.4 V (SCE). A model for the oxidation of peroxide at these electrodes is described based upon reversible binding of hydrogen peroxide to electrochemically generated palladium oxide sites.
引用
收藏
页码:520 / 526
页数:7
相关论文
共 24 条
[1]   CHARACTERIZATION OF MIXED ENZYME-MEDIATOR-CARBON PASTE ELECTRODES [J].
AMINE, A ;
KAUFFMANN, JM ;
GUILBAULT, GG ;
BACHA, S .
ANALYTICAL LETTERS, 1993, 26 (07) :1281-1299
[2]   SCREEN PRINTED GLUCOSE ELECTRODES BASED ON PLATINIZED CARBON PARTICLES AND GLUCOSE-OXIDASE [J].
CARDOSI, MF ;
BIRCH, SW .
ANALYTICA CHIMICA ACTA, 1993, 276 (01) :69-74
[3]   HYDROGEN PEROXIDE-SENSITIVE ELECTRODE BASED ON HORSERADISH PEROXIDASE-MODIFIED PLATINIZED CARBON [J].
CARDOSI, MF .
ELECTROANALYSIS, 1994, 6 (02) :89-96
[4]   FLOW-INJECTION ANALYSIS OF GLUCOSE AT AN AMPEROMETRIC GLUCOSE SENSOR-BASED ON ELECTROCHEMICAL CODEPOSITION OF PALLADIUM AND GLUCOSE-OXIDASE ON A GLASSY-CARBON ELECTRODE [J].
CHI, QJ ;
DONG, SJ .
ANALYTICA CHIMICA ACTA, 1993, 278 (01) :17-23
[5]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[6]   CARBON-FIBERS AS ELECTRODE MATERIALS FOR THE CONSTRUCTION OF PEROXIDASE-MODIFIED AMPEROMETRIC BIOSENSORS [J].
CSOREGI, E ;
GORTON, L ;
MARKOVARGA, G .
ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) :59-70
[7]   CHOLESTEROL SENSOR-BASED ON ELECTRODEPOSITION OF CATALYTIC PALLADIUM PARTICLES [J].
DONG, SJ ;
DENG, Q ;
CHENG, GG .
ANALYTICA CHIMICA ACTA, 1993, 279 (02) :235-240
[8]   AMPEROMETRIC SENSORS FOR PEROXIDE, CHOLINE, AND ACETYLCHOLINE BASED ON ELECTRON-TRANSFER BETWEEN HORSERADISH-PEROXIDASE AND A REDOX POLYMER [J].
GARGUILO, MG ;
HUYNH, N ;
PROCTOR, A ;
MICHAEL, AC .
ANALYTICAL CHEMISTRY, 1993, 65 (05) :523-528
[9]   VOLTAMMETRIC AND AMPEROMETRIC BEHAVIOR OF URIC-ACID AT BARE AND SURFACE-MODIFIED SCREEN-PRINTED ELECTRODES - STUDIES TOWARDS A DISPOSABLE URIC-ACID SENSOR [J].
GILMARTIN, MAT ;
HART, JP .
ANALYST, 1992, 117 (08) :1299-1303
[10]   AN INVESTIGATION OF THE INFLUENCES OF THE BACKGROUND MATERIAL AND LAYER THICKNESS OF SPUTTERED PALLADIUM GOLD ON CARBON ELECTRODES FOR THE AMPEROMETRIC DETERMINATION OF HYDROGEN-PEROXIDE [J].
GORTON, L ;
SVENSSON, T .
JOURNAL OF MOLECULAR CATALYSIS, 1986, 38 (1-2) :49-60