DETERMINATION OF BORON USING ION-EXCLUSION CHROMATOGRAPHY WITH POSTCOLUMN DERIVATIZATION METHOD

被引:0
作者
INOUE, Y
DATE, Y
机构
关键词
DETERMINATION OF BORN; ION EXCLUSION CHROMATOGRAPHY; POSTCOLUMN DERIVATIZATION; PHOTOMETRIC DETECTION; AZOMETHINE-H;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
1-(Salicylideneamino)-8-hydroxynaphthalene-3,6-disulfonic acid (Azomethine H) was used for the determination of boron as a reagent in a postcolumn drivatization method. Boron was separated by ion-exclusion chromatography (IEC). The eluate was subsequently mixed with Azomethine H solution to form a complex. The complex was detected at 420 nm. The reaction parameters were optimized for boron as follows: reaction coil for reaction with azomethine H, 5 m X 0.5 mm i.d.; concentration of Azomethine H, 0.5% in 1.5 mol dm-3 CH3COONH4; flow rate of the reagent, 0.8 cm3 min-1; reaction temperature, 40-degrees-C. The chromatographic conditions were as follows: column, IEC column (150 mm X 7.8 mm i.d.) packed with hydrogen form sulfonated polystyrene gel (ion exchange capacity: 3.5 meq g-1.dry); mobile phase, 1 X 10(-3) mol dm-3 sulfuric acid; flow rate, 1.0 cm3 min-1; detection wavelength, 420 nm. The detection limit (SIN=3) for boron was 7.9 X 10(-3) mg dm-3. The linear range was over 3 orders of magnitude, from 0.01 to 10 mg dm-3. The relative standard deviation (RSD) was 5.5 % (n = 10) for 0.02 mg dm-3 boron solution. The relationship between the postcolumn-IEC method and ICP-MS showed good correlation (r2 = 0.921, n = 50).
引用
收藏
页码:365 / 370
页数:6
相关论文
共 6 条
  • [1] CAPELLE R, 1991, ANAL CHIM ACTA, V24, P555
  • [2] AUTOMATIC-DETERMINATION OF BORON (0.10-10.0 MGL-1) IN RAW AND WASTE-WATERS
    EDWARDS, RA
    [J]. ANALYST, 1980, 105 (1247) : 139 - 146
  • [3] JOHN MK, 1975, ANAL LETT, V8, P559, DOI 10.1080/00032717508058240
  • [4] FLOW-INJECTION SPECTROPHOTOMETRIC DETERMINATION OF BORON IN PLANT-MATERIAL WITH AZOMETHINE-H
    KRUG, FJ
    MORTATTI, J
    PESSENDA, LCR
    ZAGATTO, EAG
    BERGAMIN, H
    [J]. ANALYTICA CHIMICA ACTA, 1981, 125 (APR) : 29 - 35
  • [5] SPECTROPHOTOMETRIC DETERMINATION OF BORON IN SILICEOUS MATERIALS WITH AZOMETHINE-H
    SCHUCKER, GD
    MAGLIOCCA, TS
    SU, YS
    [J]. ANALYTICA CHIMICA ACTA, 1975, 75 (01) : 95 - 100
  • [6] AUTOMATED-METHOD FOR THE DETERMINATION OF BORON IN WATER BY FLOW-INJECTION ANALYSIS WITH IN-LINE PRECONCENTRATION AND SPECTROPHOTOMETRIC DETECTION
    SEKERKA, I
    LECHNER, JF
    [J]. ANALYTICA CHIMICA ACTA, 1990, 234 (01) : 199 - 206