SPECTROFLUORIMETRIC DETERMINATION OF DIQUAT BY MANUAL AND FLOW-INJECTION METHODS

被引:16
|
作者
PEREZRUIZ, T
MARTINEZLOZANO, C
TOMAS, V
机构
[1] Department of Analytical Chemistry, Faculty of Sciences, University of Murcia, Murcia
关键词
FLOW SYSTEM; FLUOROMETRY; DIQUAT; HERBICIDES;
D O I
10.1016/S0003-2670(00)82483-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A reliable, highly sensitive and selective method is described for the determination of the herbicide diquat in different materials. It involves the formation of a stable radical obtained by reduction of diquat with sodium dithionite. The radical is a very fluorescent species (phi-F = 0.37), and there is a linear relationship between diquat concentration and fluorescence intensity over the range 3-900-mu-g 1(-1). The limit of detection is 0.4-mu-g 1(-1). The method can be successfully adapted as a flow system using a two-channel manifold, the peak height being proportional to the diquat concentration over the range 18-4000-mu-g 1(-1). Manual and flow-injection methods were successfully applied to the determination of diquat in commercial herbicides, waters, potatoes, flowers and soils. Both procedures were also been applied to the determination of diquat in serum and urine without prior preparation of the samples and with good results.
引用
收藏
页码:99 / 104
页数:6
相关论文
共 50 条
  • [1] Spectrofluorimetric determination of paraquat by manual and flow injection methods
    Pérez-Ruíz, T
    Martínez-Lozano, C
    Tomás, V
    Fenoll, J
    ANALYST, 1998, 123 (07) : 1577 - 1581
  • [2] SPECTROFLUORIMETRIC FLOW-INJECTION DETERMINATION OF CYANIDE
    LINARES, P
    DECASTRO, MDL
    VALCARCEL, M
    ANALYTICA CHIMICA ACTA, 1984, 161 (JUL) : 257 - 263
  • [3] Flow-injection spectrofluorimetric determination of ethylenethiourea
    Perez-Ruiz, T
    Martinez-Lozano, C
    Tomas, V
    Sanz, A
    Martin, J
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 362 (04): : 399 - 403
  • [4] Flow-injection spectrofluorimetric determination of ethylenethiourea
    Tomás Pérez-Ruiz
    Carmen Martínez-Lozano
    Virginia Tomás
    Antonio Sanz
    Jesús Martín
    Fresenius' Journal of Analytical Chemistry, 1998, 362 : 399 - 403
  • [5] FLOW-INJECTION SPECTROFLUORIMETRIC DETERMINATION OF PARACETAMOL
    CALATAYUD, JM
    BENITO, CG
    ANALYTICA CHIMICA ACTA, 1990, 231 (02) : 259 - 264
  • [6] Spectrofluorometric determination of hesperidin by manual and flow-injection methods
    T. Pérez-Ruíz
    C. Martínez-Lozano
    V. Tomás
    J. Fenoll
    Fresenius' Journal of Analytical Chemistry, 1999, 364 : 279 - 283
  • [7] Spectrofluorometric determination of hesperidin by manual and flow-injection methods
    Pérez-Ruíz, T
    Martínez-Lozano, C
    Tomás, V
    Fenoll, J
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (03): : 279 - 283
  • [8] SPECTROFLUORIMETRIC DETERMINATION OF SILICON BY FLOW-INJECTION ANALYSIS
    LINARES, P
    DECASTRO, MDL
    VALCARCEL, M
    ANALYTICA CHIMICA ACTA, 1985, 177 : 263 - 266
  • [9] Fluorimetric determination of chloroxine using manual and flow-injection methods
    PerezRuiz, T
    MartinezLozano, C
    Tomas, V
    Carpena, J
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 14 (11) : 1505 - 1511
  • [10] A Simple flow-injection spectrofluorimetric method for the determination of mercury
    Andac, Muberra
    Asan, Adem
    Tinkilic, Nihat
    Isildak, Ibrahim
    JOURNAL OF FLUORESCENCE, 2007, 17 (04) : 401 - 405