LOW-LEVEL MEASUREMENTS OF I-129 IN ENVIRONMENTAL-SAMPLES

被引:12
作者
KATAGIRI, H
NARITA, O
YAMATO, A
KINOSHITA, M
机构
[1] Power Reactor and Nuclear Fuel Development Corporation, Ibaraki-Ken, Tokai-Mura
来源
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES | 1990年 / 138卷 / 01期
关键词
D O I
10.1007/BF02049362
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical method for the determination of127I and129I in various environemntal samples has been developed. The method consists of the separation of iodine from the samples using a double layered quartz tube firing apparatus, post-irradiation purification of iodine, and measuring126I and130I by means of gamma spectrometry. The relative standard deviations of this method was less than 6%. © 1990 Akadémiai Kiadó.
引用
收藏
页码:187 / 192
页数:6
相关论文
共 7 条
[1]   IODINE-129 IN THYROID-GLANDS [J].
BOULOS, MS ;
BECKER, VJ ;
MANUEL, OK .
HEALTH PHYSICS, 1973, 24 (04) :375-378
[2]  
Brauer F.P., 1973, IAEASM18034, P1
[3]  
GABAY JJ, 1974, HEALTH PHYS, V26, P89, DOI 10.1097/00004032-197401000-00010
[4]  
MANGO PJ, 1972, IODINE 129 ENV AROUN, P72
[5]  
MATSUZEK JM, 1973, IAEASM18039
[6]   LIQUID SCINTILLATION COUNTING OF RADIOIODINE [J].
RHODES, BA .
ANALYTICAL CHEMISTRY, 1965, 37 (8P1) :995-&
[7]   IODINE-129 IN TERRESTRIAL ORES [J].
SRINIVAS.B ;
ALEXANDE.EC ;
MANUEL, OK .
SCIENCE, 1971, 173 (3994) :327-&