INTEROBSERVER VARIABILITY OF THE AORTIC ORIFICE AREA MEASURED BY ECHOCARDIOGRAPHY

被引:0
作者
IHLEN, H
MYRENG, Y
机构
来源
JOURNAL OF CARDIOVASCULAR TECHNOLOGY | 1989年 / 8卷 / 01期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:75 / 78
页数:4
相关论文
共 50 条
[11]   DETERMINATION OF AORTIC-VALVE ORIFICE AREA IN AORTIC-STENOSIS WITH 2D TRANSESOPHAGEAL ECHOCARDIOGRAPHY [J].
HOFMANN, T ;
KASPER, W ;
GEIBEL, A ;
KOESTER, W .
CIRCULATION, 1986, 74 (04) :391-391
[12]   INTRAOBSERVER AND INTEROBSERVER VARIABILITY IN THE QUANTITATION OF REGURGITANT JET AREA IN PATIENTS WITH MITRAL AND AORTIC REGURGITATION [J].
SMITH, MD ;
SPAIN, MG ;
GRAYBURN, PA ;
KWAN, L ;
NISSEN, S ;
DEMARIA, AN .
CIRCULATION, 1986, 74 (04) :131-131
[13]   Assessment of effective orifice area of prosthetic aortic valves with Doppler echocardiography: An in vivo and in vitro study [J].
Bech-Hanssen, O ;
Caidahl, K ;
Wallentin, I ;
Ask, P ;
Wranne, B .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 122 (02) :287-295
[14]   DETERMINATION OF AORTIC-VALVE ORIFICE AREA IN AORTIC-VALVE STENOSIS BY TWO-DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY [J].
HOFMANN, T ;
KASPER, W ;
MEINERTZ, T ;
SPILLNER, G ;
SCHLOSSER, V ;
JUST, H .
AMERICAN JOURNAL OF CARDIOLOGY, 1987, 59 (04) :330-335
[15]   EVIDENCE OF NO INTEROBSERVER VARIABILITY IN M-MODE ECHOCARDIOGRAPHY [J].
DELEONARDIS, V ;
CINELLI, P .
CLINICAL CARDIOLOGY, 1986, 9 (07) :324-326
[16]   Annulus Instead of LVOT Diameter Improves Agreement Between Echocardiography Effective Orifice Area and Invasive Aortic Valve Area [J].
LaBounty, Troy M. ;
Miyasaka, Rhonda ;
Chetcuti, Stanley ;
Grossman, Paul M. ;
Deeb, George Michael ;
Patel, Himanshu J. ;
Booher, Anna ;
Patel, Smita ;
Bach, David S. .
JACC-CARDIOVASCULAR IMAGING, 2014, 7 (10) :1065-1066
[17]   Planimetric Measurement of the Regurgitant Orifice Area Using Multidetector CT for Aortic Regurgitation: a Comparison with the Use of Echocardiography [J].
Jeon, Min Hee ;
Choe, Yeon Hyeon ;
Cho, Soo Jin ;
Park, Seung Woo ;
Park, Pyo Won ;
Oh, Jae K. .
KOREAN JOURNAL OF RADIOLOGY, 2010, 11 (02) :169-177
[18]   Clinical usefulness of the effective regurgitant orifice area determined by transesophageal echocardiography in patients with eccentric aortic regurgitation [J].
Sato, Y ;
Kawazoe, K ;
Kamata, J ;
Izumoto, H ;
Kitahara, H ;
Tasai, K ;
Eishi, K ;
Nakai, K ;
Nasu, M ;
Hiramori, K .
JOURNAL OF HEART VALVE DISEASE, 1997, 6 (06) :580-586
[19]   What do you mean by aortic valve area: Geometric orifice area, effective orifice area, or Gorlin area? [J].
Garcia, Damien ;
Kadem, Lyes .
JOURNAL OF HEART VALVE DISEASE, 2006, 15 (05) :601-608
[20]   SONOGRAPHIC MEASUREMENT OF ABDOMINAL AORTIC DIAMETER - INTEROBSERVER VARIABILITY [J].
YUCEL, EK ;
FILLMORE, DJ ;
KNOX, TA ;
WALTMAN, AC .
JOURNAL OF ULTRASOUND IN MEDICINE, 1991, 10 (12) :681-683