THE AIR-KERMA RATE-CONSTANT OF IR-192

被引:0
|
作者
NINKOVIC, MM
RAICEVIC, JJ
机构
[1] Institute of Nuclear Sciences “Vinca”, Belgrade
来源
HEALTH PHYSICS | 1993年 / 64卷 / 01期
关键词
IR-192; GAMMA-RADIATION; DOSIMETRY; GAMMA; RADIOACTIVITY; AIRBORNE;
D O I
10.1097/00004032-199301000-00011
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The air-kerma rate constant GAMMA(delta) (and its precursors), as one of the basic radiation characteristics of Ir-192, was determined by many authors. Analysis of accessible data on this quantity led us to the conclusion that published data strongly disagree. That is the reason we calculated this quantity on the basis of our and many other authors' gamma-ray spectral data and the latest data for mass energy-transfer coefficients for air. In this way, a value was obtained for GAMMA(delta) of 30.0 +/- 0.9 a Gy m2 s-1 Bq-1 for an unshielded Ir-192 source and 27.8 +/- 0.9 a Gy m2s -1Bq-1 for a standard packaged radioactive source taking into account attenuation of gamma rays in the platinum source wall.
引用
收藏
页码:79 / 81
页数:3
相关论文
共 50 条
  • [1] The air-kerma rate constant: Application to air-kerma measurements for homeland security
    Pibida, L.
    Minniti, R.
    Lucas, L.
    Seltzer, S. M.
    HEALTH PHYSICS, 2008, 94 (02): : 126 - 133
  • [2] Spectra and air-kerma strength for encapsulated 192Ir sources
    Borg, J
    Rogers, DWO
    MEDICAL PHYSICS, 1999, 26 (11) : 2441 - 2444
  • [3] Reference air kerma rate calibration system for high dose rate Ir-192 brachytherapy sources in Taiwan
    Chu, Wei-Han
    Yuan, Ming-Chen
    Lee, Jeng-Hung
    Lin, Yi-Chun
    RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 361 - 364
  • [4] Comparison of air-kerma strength determinations for HDR 192Ir sources
    Rasmussen, Brian E.
    Davis, Stephen D.
    Schmidt, Cal R.
    Micka, John A.
    DeWerd, Larry A.
    MEDICAL PHYSICS, 2011, 38 (12) : 6721 - 6729
  • [5] The Measurement of the Air-Kerma Rate in Air and a Solid Phantom with Ionization Chambers for a 192Ir HDR Brachytherapy Source
    Zeng, Jing
    Qu, Pengpeng
    Pang, Qingsong
    Wang, Ping
    CANCER MANAGEMENT AND RESEARCH, 2020, 12 : 10821 - 10828
  • [6] 2ND EUROMET COMPARISON OF AIR KERMA RATE AND ACTIVITY MEASUREMENTS OF IR-192 BRACHYTHERAPY WIRES
    REHER, DFG
    AALBERS, AHL
    BJERKE, H
    DRUGGE, N
    GENKA, T
    ROSSITER, MJ
    SANTRY, D
    SEPHTON, JP
    SIBBENS, G
    SEUNTJENS, J
    THIERENS, H
    VERHAEGEN, F
    WILLIAMS, TT
    WOODS, MJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 339 (1-2): : 386 - 390
  • [7] Determination of air-kerma strength for the 192Ir GammaMedplus iX pulsed-dose-rate brachytherapy source
    Riley, A. D.
    Pike, T. L.
    Micka, J. A.
    Fulkerson, R. K.
    DeWerd, L. A.
    MEDICAL PHYSICS, 2013, 40 (07)
  • [8] The Air-Kerma Strength Standard for 192Ir HDR Sources at the University of Wisconsin ADCL
    Rasmussen, B.
    Davis, S.
    Micka, J.
    DeWerd, L.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [9] Direct Calibration of a Reference chamber against the low Air Kerma Rate Primary Standard at Ir-192 energy.
    Rajan, KNG
    Palaniselvan, N
    Bhatt, BC
    Vijayam, M
    Patki, VS
    Vinatha
    Jadhavgaonkar
    Pendse, AM
    Kannan, V
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2867 - 2869
  • [10] Ion recombination for the primary standard cavity chamber of the IR-192 high dose rate reference air kerma rate standard at NPL
    Sander, T.
    Shah, A.
    Kelly, M.
    Palmans, H.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S264 - S264