EOS System - New Imaging 2D and 3D for Musculo-Skeletal Physiology and Pathology with low radiation dose and standing position

被引:36
作者
Dubousset, J. [1 ]
Charpak, G.
Dorion, I.
Skalli, W. [2 ]
Lavaste, F. [2 ,3 ]
Deguise, J. [3 ]
Kalifa, G. [4 ]
Ferey, S. [4 ]
机构
[1] Hop St Vincent De Paul, Serv Chirurg Orthoped, 74-82 Ave Denfert Rochereau, F-75674 Paris 14, France
[2] Ecole Natl Super Arts & Metiers, Paris, France
[3] Lab Rech Imagerie Orthoped, Montreal, PQ, Canada
[4] Hop St Vicente De Paul, Serv Radiol, Paris, France
来源
E-MEMOIRES DE L ACADEMIE NATIONALE DE CHIRURGIE | 2005年 / 4卷 / 04期
关键词
Low dose radiation; 3D reconstruction; standing position;
D O I
10.14607/emem.2005.4.22
中图分类号
R61 [外科手术学];
学科分类号
摘要
Very precise combined work between multidisciplinary partners (radiation engineers in physics, engineers in biomecanics, medical radiologists and orthopedic pediatric surgeons) lead to the concept and development of a new low dose radiation device named EOS. This device allows 3 main advantages : - Thanks to the gaseous detectors for X Rays designed by Georges CHARPAK (Nobel Price 1992) the reduction of doses necessary to obtain a good image of the skeletal system is important : 8 to 10 times less for 2D imaging, and 800 to 1000 times less for 3D reconstruction from CT scan cuts. - The accuracy of 3D reconstruction obtained is as good as a 3D reconstruction from CT scan cuts. -In addition, the patient gets its imaging in standing functional position thanks to the X-rays obtained from head to feet simultaneously AP and lateral. This is a big advantage compared to CT scan used only in lying position. - From this simultaneous AP and lateral X-rays of the whole body thanks to the 3D bone external envelop technique, the engineers in biomechanics allowed to obtain 3D reconstruction at every level of osteo-articular system and especially for spine in standing position within an acceptable period of time (15 to 30 minutes). EOS (in spite of the evolution of standing MRI) allows more precise bone reconstruction in orthopedics especially at the level of spine, pelvis and lower limbs, giving new consideration for physiology, physio-pathology and therapeutics.
引用
收藏
页码:22 / 27
页数:6
相关论文
共 8 条
[1]   The new effective detector for digital scanning radiography [J].
Babichev, EA ;
Baru, SE ;
Groshev, VR ;
Khabakhpashev, AG ;
Leonov, VV ;
Neustroev, VA ;
Porosev, VV ;
Savinov, GA ;
Shekhtman, LI .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 513 (1-2) :57-60
[2]   Risk of cancer from diagnostic X-rays:: estimates for the UK and 14 other countries [J].
Berrington de González, A ;
Darby, S .
LANCET, 2004, 363 (9406) :345-351
[3]  
Deschenes S, 2003, SPIE MED IMAGING
[4]   Evaluation of a new low-dose digital X-ray device: first dosimetric and clinical results in children [J].
Kalifa, G ;
Charpak, Y ;
Maccia, C ;
Fery-Lemonnier, E ;
Bloch, J ;
Boussard, JM ;
Attal, M ;
Dubousset, J ;
Adamsbaum, C .
PEDIATRIC RADIOLOGY, 1998, 28 (07) :557-561
[5]  
Laporte S., 2003, Computer Methods in Biomechanics and Biomedical Engineering, V6, P1, DOI 10.1080/1025584031000065956
[6]  
Le Bras A, 2002, Stud Health Technol Inform, V91, P286
[7]   3D reconstruction method from biplanar radiography using non-stereocorresponding points and elastic deformable meshes [J].
Mitton, D ;
Landry, C ;
Véron, S ;
Skalli, W ;
Lavaste, F ;
De Guise, JA .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (02) :133-139
[8]   Fast accurate stereoradiographic 3D-reconstruction of the spine using a combined geometric and statistic model [J].
Pomero, V ;
Mitton, D ;
Laporte, S ;
de Guise, JA ;
Skalli, W .
CLINICAL BIOMECHANICS, 2004, 19 (03) :240-247