MEASUREMENT REPRODUCIBILITY OF 2 COMMERCIAL KNEE TEST DEVICES

被引:25
作者
TORZILLI, PA
PANARIELLO, RA
FORBES, A
SANTNER, TJ
WARREN, RF
机构
[1] CORNELL UNIV, MED CTR,NEW YORK HOSP,HOSP SPECIAL SURG, SPORTS MED SERV, NEW YORK, NY 10021 USA
[2] CORNELL UNIV, DEPT OPERAT RES, ITHACA, NY 14853 USA
[3] OHIO STATE UNIV, DEPT STAT, COLUMBUS, OH 43210 USA
关键词
KT-1000; GENUCOM; REPRODUCIBILITY; KNEE MOTION; VARIANCE;
D O I
10.1002/jor.1100090513
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective evaluation of patients' knee motion using mechanical devices, whether for diagnostic purposes or for assessing rehabilitative procedures, requires that these devices be reproducible, in order to avoid errors independent of the patients' condition. This study prospectively evaluates the reproducibility of two commercial knee test systems, the KT 1000 Knee Ligament Arthrometer and the Genucom Knee Analysis System, by performing repeated measurements on twenty normal men. Average knee motion, between-subject variance, and within-subject variance were determined by performing repeat tests on the same day and one week later. No significant difference was found between measurements taken on the two different test days, but the within-subject variation was high. We found that larger applied forces or moments resulted in a larger variation in mean displacements. However, the percent variation about the mean (coefficient of variation) decreased with increasing applied loads. The coefficient of variation for the KT 1000 varied from 8 to 33% and for the Genucom, from 13 to 87%. On an individual basis, large variations were found in repeated measures for both devices. To minimize errors, we recommend that repeated tests be performed, higher forces and moments utilized, and specific flexion angles be used for each device and test. Even under these conditions, caution must be exercised when evaluating individual subjects.
引用
收藏
页码:730 / 737
页数:8
相关论文
共 15 条
[1]  
ANDERSSON C, 1990, CLIN ORTHOP RELAT R, V256, P178
[2]   STANDARDIZED BIOMECHANICAL MEASUREMENT FOR VARUS-VALGUS STIFFNESS AND ROTATION IN NORMAL KNEES [J].
BRYANT, JT ;
COOKE, TDV .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1988, 6 (06) :863-870
[3]   INSTRUMENTED MEASUREMENT OF ANTERIOR LAXITY OF THE KNEE [J].
DANIEL, DM ;
MALCOM, LL ;
LOSSE, G ;
STONE, ML ;
SACHS, R ;
BURKS, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (05) :720-726
[4]   ACCURACY AND REPRODUCIBILITY OF INSTRUMENTED KNEE-DRAWER TESTS [J].
EDIXHOVEN, P ;
HUISKES, R ;
DEGRAAF, R ;
VANRENS, TJG ;
SLOOFF, TJ .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1987, 5 (03) :378-387
[5]   IS THE KT1000 KNEE LIGAMENT ARTHROMETER RELIABLE [J].
FORSTER, IW ;
WARRENSMITH, CD ;
TEW, M .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1989, 71 (05) :843-847
[6]   AN INVITRO BIOMECHANICAL EVALUATION OF ANTERIOR-POSTERIOR MOTION OF THE KNEE - TIBIAL DISPLACEMENT, ROTATION, AND TORQUE [J].
FUKUBAYASHI, T ;
TORZILLI, PA ;
SHERMAN, MF ;
WARREN, RF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (02) :258-264
[7]   GENUCOM, KT-1000, AND STRYKER KNEE LAXITY MEASURING DEVICE COMPARISONS - DEVICE REPRODUCIBILITY AND INTERDEVICE COMPARISON IN ASYMPTOMATIC SUBJECTS [J].
HIGHGENBOTEN, CL ;
JACKSON, A ;
MESKE, NB .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1989, 17 (06) :743-746
[8]  
JACOBSEN K, 1981, ACTA ORTHOP SCAND, V52, P1
[9]   ANATOMY AND FUNCTION OF ANTERIOR CRUCIATE LIGAMENT - AS DETERMINED BY CLINICAL AND MORPHOLOGICAL STUDIES [J].
KENNEDY, JC ;
WEINBERG, HW ;
WILSON, AS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1974, A 56 (02) :223-235
[10]   THE STRYKER KNEE ARTHROMETER IN CLINICAL-PRACTICE [J].
KING, JB ;
KUMAR, SJ .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1989, 17 (05) :649-650