Assessment of electricity generation by wind power in nine costal sites in Malaysia

被引:4
作者
Khatib, Tamer [1 ]
Sopian, K. [2 ]
Ibrahim, Mohd Zamri [3 ]
机构
[1] Univ Kebangsaan Malaysia, Fac Engn & Built Environm, Dept Elect Elect & Syst Engn, Bangi 43600, Selangor, Malaysia
[2] Univ Kebangsaan Malaysia, Solar Energy Res Inst, Bangi 43600, Selangor, Malaysia
[3] Univ Malaysia Terengganu, Fac Sci & Technol, Dept Engn Sci, Kuala Terengganu, Terengganu, Malaysia
关键词
wind power systems; wind power; feasibility of wind power systems; Malaysia;
D O I
10.1080/01430750.2012.740428
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this article, the wind power potential in Malaysia is examined. Hourly wind speed data for nine sites in Malaysia are used to optimally design wind power systems for remote housing electrification. These nine sites are Bintulu, Kota Kinabalu, Kuala Terengganu, Kuching, Kudat, Mersing, Sandakan, Tawau and Pulau Langkawi. The designed wind power systems are supposed to supply hourly load demand 6.13 kWh/day, 0.52kW peak with 1% loss of load probability. The unit cost of the energy produced by each system is calculated and compared to the unit cost of the energy produced by a standalone photovoltaic (PV) power systems and a diesel generator power systems. The results show that the average unit cost of the energy produced by a wind power system in Malaysia is 1.6-7.29 USD/kWh while it is 0.35-0.5 USD/kWh and 0.27-0.30 USD/kWh for PV power system and diesel generator power system, respectively. Based on this, the use of wind power systems as standalone systems is not recommended for the selected sites.
引用
收藏
页码:138 / 144
页数:7
相关论文
共 11 条
[1]   Review and comparison study of hybrid diesel/solar/hydro/fuel cell energy schemes for a rural ICT Telecenter [J].
Abdullah, M. O. ;
Yung, V. C. ;
Anyi, M. ;
Othman, A. K. ;
Hamid, K. B. Ab. ;
Tarawe, J. .
ENERGY, 2010, 35 (02) :639-646
[2]   On the policy of photovoltaic and diesel generation mix for an off-grid site: East Malaysian perspectives [J].
Ajan, CW ;
Ahmed, SS ;
Ahmad, HB ;
Taha, F ;
Zin, AABM .
SOLAR ENERGY, 2003, 74 (06) :453-467
[3]  
El-Shobokshy M. S., 1991, International Journal of Ambient Energy, V12, P39, DOI 10.1080/01430750.1991.9675187
[4]   Optimal configuration assessment of renewable energy in Malaysia [J].
Haidar, Ahmed M. A. ;
John, Priscilla N. ;
Shawal, Mohd .
RENEWABLE ENERGY, 2011, 36 (02) :881-888
[5]   Optimization of a PV/wind micro-grid for rural housing electrification using a hybrid iterative/genetic algorithm: Case study of Kuala Terengganu, Malaysia [J].
Khatib, Tamer ;
Mohamed, Azah ;
Sopian, K. .
ENERGY AND BUILDINGS, 2012, 47 :321-331
[6]   Optimal sizing of building integrated hybrid PV/diesel generator system for zero load rejection for Malaysia [J].
Khatib, Tamer ;
Mohamed, A. ;
Sopian, K. ;
Mahmoud, M. .
ENERGY AND BUILDINGS, 2011, 43 (12) :3430-3435
[7]   Performance analysis of hybrid photovoltaic/diesel energy system under Malaysian conditions [J].
Lau, K. Y. ;
Yousof, M. F. M. ;
Arshad, S. N. M. ;
Anwari, M. ;
Yatim, A. H. M. .
ENERGY, 2010, 35 (08) :3245-3255
[8]  
Radhwan A. M., 1994, International Journal of Ambient Energy, V15, P123, DOI 10.1080/01430750.1994.9675644
[9]   Techno-economical optimization of hybrid pv/wind/battery system using Neuro-Fuzzy [J].
Rajkumar, R. K. ;
Ramachandaramurthy, V. K. ;
Yong, B. L. ;
Chia, D. B. .
ENERGY, 2011, 36 (08) :5148-5153
[10]   Economical, environmental and technical analysis of building integrated photovoltaic systems in Malaysia [J].
Seng, Lim Yun ;
Lalchand, G. ;
Lin, Gladys Mak Sow .
ENERGY POLICY, 2008, 36 (06) :2130-2142