Advanced Motion Correction Methods in PET (Review Article)

被引:0
作者
Rahmim, Arman [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21218 USA
来源
IRANIAN JOURNAL OF NUCLEAR MEDICINE | 2005年 / 13卷 / 02期
关键词
Motion tracking; Motion correction; Cardiac gating; Respiratory gating; 4D Image reconstruction; High resolution PET;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of motion (most often studies in PET brain imaging), conventional motion-correction algorithms have relied on extraction of the motion information from the emission data itself. However, the accuracy of motion compensation in this approach is degraded by the noisy nature of the emission data. Subsequently, advanced methods, as reviewed in this work, make use of external real-time measurements of motion. Various image-based and projection-based correction methods have been discussed and compared. The paper also reviews recent and novel applications that perform corrections for cardiac and respiratory motions. Unlike conventional gating schemes, in which the cardiac and respiratory gated frames are independently reconstructed (resulting in noisy images), the reviewed methods are seen to follow a common trend of seeking to produce images of higher quality by making collective use of all the gated frames (and the estimated motion). As an observation, a general theme in motion-correction methods is seen to be the use of increasingly sophisticated software to make use of existing advanced hardware. In this sense, this field is very open to future novel ideas (hardware, and especially software) aimed at improving motion detection, characterization and compensation.
引用
收藏
页码:1 / 17
页数:17
相关论文
共 48 条
  • [1] EFFECTS OF SPONTANEOUS RESPIRATION ON LEFT-VENTRICULAR FUNCTION ASSESSED BY ECHOCARDIOGRAPHY
    ANDERSEN, K
    VIKMO, H
    [J]. CIRCULATION, 1984, 69 (05) : 874 - 879
  • [2] Beach DB, 2004, T NUCL MED, V51, P2693
  • [3] The design and implementation of a motion correction scheme for neurological PET
    Bloomfield, PM
    Spinks, TJ
    Reed, J
    Schnorr, L
    Westrip, AM
    Livieratos, L
    Fulton, R
    Jones, T
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (08) : 959 - 978
  • [4] Boucher L, 2004, J NUCL MED, V45, P214
  • [5] Brankov JG, 2004, IEEE NUCL SCI CONF R, P2845
  • [6] Brankov JG, 2003, IEEE NUCL SCI CONF R, P1380
  • [7] An accurate method for correction of head movement in PET
    Bühler, P
    Just, U
    Will, E
    Kotzerke, J
    van den Hoff, J
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (09) : 1176 - 1185
  • [8] Three-dimensional motion estimation with image reconstruction for gated cardiac ECT
    Cao, ZX
    Gilland, DR
    Mari, BA
    Jaszczak, RJ
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (03) : 384 - 388
  • [9] Design of a motion-compensation OSEM list-mode algorithm for resolution-recovery reconstruction for the HRRT
    Carson, RE
    Barker, WC
    Liow, JS
    Johnson, CA
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3281 - 3285
  • [10] DAUBE-WITHERSPOON M E, 1990, Journal of Nuclear Medicine, V31, P816