AUTOMATED DATA-COLLECTION AND ANALYSIS SYSTEM FOR MOSFET RADIATION DETECTORS

被引:38
作者
GLADSTONE, DJ
CHIN, LM
机构
[1] Joint Center For Radiation Therapy, Department of Radiation Therapy, Harvard Medical School, Boston
关键词
MOSFET; MINIATURE DOSIMETER; INVIVO DOSIMETRY; RADIOIMMUNOTHERAPY; BRACHYTHERAPY;
D O I
10.1118/1.596731
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Metal oxide semiconductor field effect transistors (MOSFET) have been used as radiation dosimeters. Because of their small detector size, minimal power requirements, and signal integration characteristics, they offer unique possibilities as real-time dose monitors in radiotherapy. An automated data collection and analysis system for use with MOSFET radiation dosimeters has been designed and built. The objective was to design a system which can acquire and process the MOSFET signals in real time, in any radiation field encountered in radiotherapy. In particular, major problems have been solved arising from the intrinsic drifts of the MOSFET signal during low dose rate measurements. These signal drifts are significant when the MOSFET detector is used in applications such as on-line monitoring of radiation dose delivery in brachytherapy or radioimmunotherapy. The data collection and analysis system includes a portable IBM-compatible personal computer fitted with digital-to-analog and analog-to-digital converter boards. A single-chip programmable current supply is used to power the MOSFET dosimeters. Intrinsic and extrinsic drifts in signal due to ion diffusion and electron tunneling are corrected by deconvolution of the collected data in real time or after data collection. The data acquisition system and signal-processing methodologies are described.
引用
收藏
页码:542 / 548
页数:7
相关论文
共 24 条
  • [11] A SYSTEM FOR STEREOTACTIC RADIOSURGERY WITH A LINEAR-ACCELERATOR
    LUTZ, W
    WINSTON, KR
    MALEKI, N
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (02): : 373 - 381
  • [12] Ma T.P., 1989, IONIZING RAD EFFECTS
  • [13] MODELING OF MOS RADIATION AND POST IRRADIATION EFFECTS
    NEAMEN, DA
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (06) : 1439 - 1443
  • [14] CHARACTERISTICS OF SILICON DIODES AS PATIENT DOSIMETERS IN EXTERNAL RADIATION-THERAPY
    NILSSON, B
    RUDEN, BI
    SORCINI, B
    [J]. RADIOTHERAPY AND ONCOLOGY, 1988, 11 (03) : 279 - 288
  • [15] MEASUREMENTS OF DOSE DISTRIBUTIONS IN SMALL BEAMS OF 6 MV X-RAYS
    RICE, RK
    HANSEN, JL
    SVENSSON, GK
    SIDDON, RL
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (09) : 1087 - 1099
  • [16] EVALUATION OF CLINICAL USE OF TLD
    RUDEN, BI
    [J]. ACTA RADIOLOGICA-THERAPY PHYSICS BIOLOGY, 1976, 15 (05): : 447 - 464
  • [17] RUDEN BI, 1975, EXCERPTA MED, V2, P495
  • [18] THE ROLE OF HYDROGEN IN RADIATION-INDUCED DEFECT FORMATION IN POLYSILICON GATE MOS DEVICES
    SCHWANK, JR
    FLEETWOOD, DM
    WINOKUR, PS
    DRESSENDORFER, PV
    TURPIN, DC
    SANDERS, DT
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (06) : 1152 - 1158
  • [19] STREUBEL G, 1988, NUCL INSTRUM METH A, V274, P194
  • [20] WARD AK, 1989, 40TH C INT ASTR FED