QUANTIZATION-ERROR IN CLINICAL PURE-TONE AUDIOMETRY

被引:12
作者
LEIJON, A
机构
[1] The Department of Information Theory, Chalmers University of Technology, Gothenburg
来源
SCANDINAVIAN AUDIOLOGY | 1992年 / 21卷 / 02期
关键词
AUDIOMETRY; ACCURACY; RELIABILITY;
D O I
10.3109/01050399209045989
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
The current clinical procedure for pure-tone audiometry was analysed for statistical measurement errors. Theoretically, the root-mean-square (RMS) error in a single threshold measurement is always greater than the standard deviation (SD) of measured intra-individual test-retest differences, divided by the square root of two. The RMS error includes an additional quantization component, caused by the finite step size between presented signal levels. In Monte-Carol simulations with 2-dB and 5-dB steps the quantization error was negligible compared with other errors. Therefore, the single-test RMS error can be estimated with sufficient accuracy from the test-retest SD. The simulated single-test RMS error decreased from about 2.7 dB about 2.3 dB when the audiometric step size was reduced from 5 dB to 2 dB. Hearing thresholds appeared to be about 1.7 dB better with 2-dB steps than with 5-dB steps.
引用
收藏
页码:103 / 108
页数:6
相关论文
共 50 条
  • [21] The Benefit of Air Conduction Pure-Tone Audiometry as a Screening Method for Hearing Loss over the VAS Score
    Giotakis, Aris I.
    Mariolis, Lambros
    Koulentis, Ioannis
    Mpoutris, Christos
    Giotakis, Evangelos I.
    Apostolopoulou, Aikaterini
    Papaefstathiou, Efstathios
    DIAGNOSTICS, 2024, 14 (01)
  • [22] One-eartip solution for pure-tone audiometry and acoustic immittance measurements: using insert earphone with an immittance probe ear tip
    Ramatsoma, Hlologelo
    Koekemoer, Dirk
    Clark, Jackie L.
    Malan, Keagan
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2022, 61 (03) : 251 - 257
  • [23] Distribution characteristics of normal pure-tone thresholds
    Margolis, Robert H.
    Wilson, Richard H.
    Popelka, Gerald R.
    Eikelboom, Robert H.
    Swanepoel, De Wet
    Saly, George L.
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2015, 54 (11) : 796 - 805
  • [24] The Acceptable Noise Level and the Pure-Tone Audiogram
    Brannstroma, K. Jonas
    Olsen, Steen Ostergaard
    AMERICAN JOURNAL OF AUDIOLOGY, 2017, 26 (01) : 80 - 87
  • [25] Pure-tone auditory threshold in school children
    Mueller, Reinhard
    Fleischer, Gerald
    Schneider, Joachim
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2012, 269 (01) : 93 - 100
  • [26] Pure-tone auditory threshold in school children
    Reinhard Müller
    Gerald Fleischer
    Joachim Schneider
    European Archives of Oto-Rhino-Laryngology, 2012, 269 : 93 - 100
  • [27] THE WELCH ALLYN AUDIOSCOPE AND MICROTYMP - THEIR ACCURACY AND THAT OF PNEUMATIC OTOSCOPY, TYMPANOMETRY AND PURE-TONE AUDIOMETRY AS PREDICTORS OF OTITIS-MEDIA WITH EFFUSION
    VAUGHANJONES, R
    MILLS, RP
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1992, 106 (07) : 600 - 602
  • [28] Significance of deviations in hearing thresholds in pure-tone audiograms
    Steffens, T.
    Steffens, L. M.
    HNO, 2020, 68 (07) : 517 - 525
  • [29] Pure-tone audiometry without bone-conduction thresholds: using the digits-in-noise test to detect conductive hearing loss
    De Sousa, Karina C.
    Smits, Cas
    Moore, David R.
    Myburgh, Hermanus Carel
    Swanepoel, De Wet
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2020, 59 (10) : 801 - 808
  • [30] Correlation between DPOAE I/O functions and pure-tone thresholds
    Campos, Ualace de Paula
    Mamede Carvallo, Renata Mota
    BRAZILIAN JOURNAL OF OTORHINOLARYNGOLOGY, 2011, 77 (06) : 754 - 760