QUANTIZATION-ERROR IN CLINICAL PURE-TONE AUDIOMETRY

被引:12
作者
LEIJON, A
机构
[1] The Department of Information Theory, Chalmers University of Technology, Gothenburg
来源
SCANDINAVIAN AUDIOLOGY | 1992年 / 21卷 / 02期
关键词
AUDIOMETRY; ACCURACY; RELIABILITY;
D O I
10.3109/01050399209045989
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
The current clinical procedure for pure-tone audiometry was analysed for statistical measurement errors. Theoretically, the root-mean-square (RMS) error in a single threshold measurement is always greater than the standard deviation (SD) of measured intra-individual test-retest differences, divided by the square root of two. The RMS error includes an additional quantization component, caused by the finite step size between presented signal levels. In Monte-Carol simulations with 2-dB and 5-dB steps the quantization error was negligible compared with other errors. Therefore, the single-test RMS error can be estimated with sufficient accuracy from the test-retest SD. The simulated single-test RMS error decreased from about 2.7 dB about 2.3 dB when the audiometric step size was reduced from 5 dB to 2 dB. Hearing thresholds appeared to be about 1.7 dB better with 2-dB steps than with 5-dB steps.
引用
收藏
页码:103 / 108
页数:6
相关论文
共 50 条
  • [1] Influence of the type of acoustic transducer in pure-tone audiometry
    Born, Nathalia Montandon
    Marciano, Mariane da Silva
    Mass, Stephanie da Costa
    Camargo da Silva, Daniela Polo
    Scharlach, Renata Coelho
    CODAS, 2022, 34 (03):
  • [2] Utilizing True Wireless Stereo Earbuds in Automated Pure-Tone Audiometry
    Guo, Zhenyu
    Yu, Guangzheng
    Zhou, Huali
    Wang, Xianren
    Lu, Yigang
    Meng, Qinglin
    TRENDS IN HEARING, 2021, 25
  • [3] New Method for Pure-Tone Audiometry Using Electrooculogram: A Proof-of-Concept Study
    Kim, Do Yeon
    Kwon, Jinuk
    Kim, Joo-Young
    Cha, Ho-Seung
    Kim, Yong-Wook
    Kim, In Young
    Im, Chang-Hwan
    SENSORS, 2018, 18 (11)
  • [4] Evaluation of hearing with pure-tone audiometry in alopecia areata patients
    Erdogan, Hilal Kaya
    Acer, Ersoy
    Haklu, Ahmet
    Bulur, Isil
    Incesulu, Armagan
    Pinarbasli, Ozgur
    Bilgin, Muzaffer
    TURKDERM-TURKISH ARCHIVES OF DERMATOLOGY AND VENEROLOGY, 2019, 53 (01): : 19 - 23
  • [5] A COMPARISON OF SPEECH AUDIOMETRY AND PURE-TONE AUDIOMETRY IN PATIENTS WITH SECRETORY OTITIS-MEDIA
    PRINGLE, MB
    THOMPSON, A
    REDDY, K
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1993, 107 (09) : 787 - 789
  • [6] Hearing Tests Based on Biologically Calibrated Mobile Devices: Comparison With Pure-Tone Audiometry
    Masalski, Marcin
    Grysinski, Tomasz
    Krecicki, Tomasz
    JMIR MHEALTH AND UHEALTH, 2018, 6 (01):
  • [7] EXPLORATION OF COCHLEAR FUNCTION BY OTOACOUSTIC EMISSIONS - RELATIONSHIP TO PURE-TONE AUDIOMETRY
    AVAN, P
    BONFILS, P
    LOTH, D
    TEYSSOU, M
    MENGUY, C
    PROGRESS IN BRAIN RESEARCH, 1993, 97 : 67 - 75
  • [8] Otoacoustic emissions, pure-tone audiometry, and self-reported hearing
    Engdahl, Bo
    Tambs, Kristian
    Hoffman, Howard J.
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2013, 52 (02) : 74 - 82
  • [9] Accuracy of automated pure-tone audiometry in population-based samples of older adults
    Hoff, Maria
    Gothberg, Hanna
    Tengstrand, Tomas
    Rosenhall, Ulf
    Skoog, Ingmar
    Sadeghi, Andre
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2024, 63 (08) : 622 - 630
  • [10] Comparison between auditory steady-state responses and pure-tone audiometry
    Komazec, Zoran
    Lemajic-Komazec, Slobodanka
    Jovic, Rajko
    Nadj, Congor
    Jovancevic, Ljiljana
    Savovic, Slobodan
    VOJNOSANITETSKI PREGLED, 2010, 67 (09) : 761 - 765