A REFLECTANCE ANISOTROPY SPECTROMETER FOR REAL-TIME MEASUREMENTS

被引:46
|
作者
ACHER, O [1 ]
DREVILLON, B [1 ]
机构
[1] ECOLE POLYTECH,PHYS INTERFACES & COUCHES MINCES LAB,CNRS,UPR 258,F-91128 PALAISEAU,FRANCE
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1992年 / 63卷 / 11期
关键词
D O I
10.1063/1.1143398
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new reflectance anisotropy (RA) spectrometer, in the 0.23-0.83-mum range, is presented. The numerous similarities with phase-modulated ellipsometry (PME) are emphasized. In particular, the RA spectrometer takes advantage of the high-frequency modulation (50 kHz) provided by a photoelastic modulator. The use of optical fibers in both optical arms allows an increase of the compactness of the spectrometer. Four detectors can be used simultaneously providing the real-time spectroscopic capability. The numerical data acquisition system of the detected signal is based on the use of a high precision analog-digital converter and a fast Fourier transform processor. However, as compared to ellipsometry, RA can be only sensitive to the crystal surface. The adaptation of RA to a III-V growth reactor by metalorganic chemical vapor deposition is described in detail. The high sensitivity of the RA spectrometer is emphasized. In particular real-time variations of the RA signal ranging from 10(-4) to 10(-3) are reported. Then, the various RA techniques are compared. In particular, it is shown that this RA spectrometer allows the determination of both the real and the imaginary part of the signal. Finally the origin of the RA signal is discussed.
引用
收藏
页码:5332 / 5339
页数:8
相关论文
共 50 条
  • [1] Real-time reflectance anisotropy spectroscopy of GaAs homoepitaxy
    Lastras-Martinez, A.
    Guevara-Macias, L. E.
    Santiago-Garcia, J. G.
    Ortega-Gallegos, J.
    Ruiz-Alvarado, I. A.
    Martinez-Espinosa, R.
    Ariza-Flores, D.
    Castro-Garcia, R.
    Lopez-Estopier, R. E.
    Balderas-Navarro, R. E.
    Lastras-Martinez, L. F.
    APPLIED OPTICS, 2020, 59 (13) : D39 - D42
  • [2] PHOTOINDUCED ANISOTROPY - NEW PHOTOPOLARIMETRIC SETUP FOR REAL-TIME MEASUREMENTS
    NIKOLOVA, L
    TODOROV, T
    SHARLANDJIEV, P
    STOYANOV, S
    APPLIED OPTICS, 1992, 31 (31): : 6698 - 6701
  • [3] A rapid reflectance anisotropy spectrometer
    Harrison, P
    Farrell, T
    Maunder, A
    Smith, CI
    Weightman, P
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2001, 12 (12) : 2185 - 2191
  • [4] Real-time control of quantum dot laser growth using reflectance anisotropy spectroscopy
    Pohl, UW
    Pötschke, K
    Kaiander, I
    Zettler, JT
    Bimberg, D
    JOURNAL OF CRYSTAL GROWTH, 2004, 272 (1-4) : 143 - 147
  • [5] Real-Time Linux driving a spectrometer
    Teuben, P
    Harris, A
    Isaak, K
    Morgan, J
    Zmuidzinas, J
    ASTRONOMICAL DATA ANALYSIS SOFTWARE AND SYSTEMS VIII, 1999, 172 : 99 - 102
  • [6] Real-Time Multidetector Neutron Spectrometer
    Drejzin, V. E.
    Grimov, A. A.
    Logvinov, D. I.
    Journal of Applied Spectroscopy, 2016, 83 (03) : 454 - 459
  • [7] Real-Time Multidetector Neutron Spectrometer
    V. E. Drejzin
    A. A. Grimov
    D. I. Logvinov
    Journal of Applied Spectroscopy, 2016, 83 : 454 - 459
  • [8] Real-time growth monitoring of InGaAs/InP-HBT structures with reflectance anisotropy spectroscopy
    Arens, M
    Kurpas, P
    Ressel, P
    Weyers, M
    THIN SOLID FILMS, 1998, 313 : 609 - 613
  • [9] Real-time monitoring of MOVPE device growth by reflectance anisotropy spectroscopy and related optical techniques
    Zettler, JT
    Haberland, K
    Zorn, M
    Pristovsek, M
    Richter, W
    Kurpas, P
    Weyers, M
    JOURNAL OF CRYSTAL GROWTH, 1998, 195 (1-4) : 151 - 162
  • [10] Real-time growth monitoring of InGaAs/InP-HBT structures with reflectance anisotropy spectroscopy
    Arens, M.
    Kurpas, P.
    Ressel, P.
    Weyers, M.
    Thin Solid Films, 1998, 313-314 (1-2): : 609 - 613