MEASUREMENT OF AIRWAY WALL BLOOD-FLOW IN SHEEP BY LASER-DOPPLER FLOWMETRY - INTERPRETATION AND PROBLEMS

被引:12
|
作者
GODDEN, DJ
WAGNER, EM
PARE, PD
MITZNER, W
BAILE, EM
机构
[1] UNIV BRITISH COLUMBIA,ST PAULS HOSP,PULM RES LAB,1081 BURRARD ST,VANCOUVER V6Z 1Y6,BC,CANADA
[2] JOHNS HOPKINS UNIV,FRANCIS SCOTT KEY MED CTR,DEPT MED,DIV PULM MED,BALTIMORE,MD 21205
关键词
BRONCHIAL AND TRACHEAL BLOOD FLOW; BRONCHIAL ARTERY PERFUSION; BRONCHOSCOPY;
D O I
10.1152/jappl.1991.70.2.641
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We have used laser-Doppler flowmetry (LDF), a technique that detects movement of erythrocytes, to measure tracheal and bronchial wall blood flow in anesthetized openchest sheep. LDF derives continuous measurements noninvasively, although fiber-optic bronchoscopy is necessary to introduce the LDF probe into the airways. The response of the LDF flow signals at four regions of the airway walls to varying bronchial arterial flow rates was examined in both live and dead sheep by cannulation and subsequent perfusion of the common bronchial artery at different flow rates by use of a roller pump. In the live sheep, variations in bronchial arterial blood flow resulted in variations in LDF signals in the principal bronchus and in lobar and segmental bronchi but not in the trachea. In the dead sheep, variations in bronchial arterial blood flow resulted in variations in LDF signals in all four regions. Within regions, the average response of the LDF signals to varying bronchial blood flow rates was approximately linear in both live and dead sheep, but considerable site-to-site variation in response was observed. In the live sheep, significant LDF signals were observed when the bronchial arterial flow was set to zero and when the bronchial artery was perfused with dextran solution, which would in theory be expected to produce no LDF signal. A small LDF signal was also detected under zero flow conditions in the dead sheep. These observations suggest that the LDF technique, in addition to detecting blood flow from the bronchial artery, also detects background noise and/or collateral circulation. The residual signal at zero flow and after death and the site-to-site variability represent major problems that preclude accurate measurement of changes in airway blood flow with this technique. These data suggest that in its present form LDF will not prove useful in the measurement of airway wall blood flow during bronchoscopy.
引用
收藏
页码:641 / 649
页数:9
相关论文
共 50 条
  • [21] RAPID AUTOREGULATION OF CEREBRAL BLOOD-FLOW - A LASER-DOPPLER FLOWMETRY STUDY
    FLORENCE, G
    SEYLAZ, J
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1992, 12 (04): : 674 - 680
  • [22] BLOOD-FLOW MAPPING OF ORAL-TISSUES BY LASER-DOPPLER FLOWMETRY
    HOKE, JA
    BURKES, EJ
    WHITE, JT
    DUFFY, MB
    KLITZMAN, B
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1994, 23 (05) : 312 - 315
  • [23] CONTINUOUS MEASUREMENT OF CEREBRAL CORTICAL BLOOD-FLOW BY LASER-DOPPLER FLOWMETRY IN A RAT STROKE MODEL
    DIRNAGL, U
    KAPLAN, B
    JACEWICZ, M
    PULSINELLI, W
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1989, 9 (05): : 589 - 596
  • [24] Adaptation of laser-Doppler flowmetry to measure cerebral blood flow in the fetal sheep
    Lan, J
    Hunter, CJ
    Murata, T
    Power, GG
    JOURNAL OF APPLIED PHYSIOLOGY, 2000, 89 (03) : 1065 - 1071
  • [25] ASSESSMENT OF MUSCLE BLOOD-FLOW BY LASER-DOPPLER FLOWMETRY DURING HEMORRHAGE IN SHR
    LOMBARD, JH
    ROMAN, RJ
    AMERICAN JOURNAL OF PHYSIOLOGY, 1990, 259 (03): : H860 - H865
  • [26] BLOOD-FLOW IN THE HUMAN ACHILLES-TENDON ASSESSED BY LASER-DOPPLER FLOWMETRY
    ASTROM, M
    WESTLIN, N
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1994, 12 (02) : 246 - 252
  • [27] HUMAN GASTRIC-MUCOSAL BLOOD-FLOW BY ENDOSCOPIC LASER-DOPPLER FLOWMETRY
    GANA, TJ
    SOENEN, GM
    KOO, J
    GASTROINTESTINAL ENDOSCOPY, 1989, 35 (02) : 152 - 153
  • [28] MONITORING OF SPINAL-CORD BLOOD-FLOW (SCBF) WITH LASER-DOPPLER FLOWMETRY
    LINDSBERG, PJ
    ONEILL, JT
    PAAKKARI, IA
    HALLENBECK, JM
    FEUERSTEIN, G
    STROKE, 1989, 20 (01) : 134 - 134
  • [29] MEASUREMENT OF SKIN BLOOD-FLOW USING LASER DOPPLER FLOWMETRY
    SVENSSON, H
    JONSSON, BA
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1986, 5 (2-3): : 205 - 205
  • [30] EFFECT OF NIMODIPINE ON THE AUTOREGULATION OF CEREBRAL BLOOD-FLOW STUDIED BY LASER-DOPPLER FLOWMETRY
    FLORENCE, G
    BONVENTO, G
    ROUCHER, P
    CHARBONNE, R
    SEYLAZ, J
    BRAIN RESEARCH, 1993, 625 (02) : 301 - 306