MATERNAL SERUM ALPHA-FETOPROTEIN SCREENING - FURTHER CONSIDERATION OF LOW-VOLUME TESTING

被引:1
作者
STRICKLAND, DM
BUTZIN, CA
WIANS, FH
机构
[1] WILFORD HALL USAF MED CTR,SGHLCC,DEPT PATHOL,LACKLAND AFB,TX 78236
[2] WILFORD HALL USAF MED CTR,SGHO,DEPT OBSTET & GYNECOL,LACKLAND AFB,TX 78236
[3] WILFORD HALL USAF MED CTR,SGS,CLIN INVEST DIRECTORATE,LACKLAND AFB,TX 78236
关键词
MATERNAL SERUM ALPHA-FETOPROTEIN; LOW-VOLUME MATERNAL SERUM ALPHA-FETOPROTEIN TESTING; NEURAL TUBE DEFECTS; QUALITY CONTROL;
D O I
10.1016/0002-9378(91)90502-I
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Unrecognized assay drift that may occur during low-volume (fewer than 500 specimens per week) maternal serum alpha-fetoprotein testing could result in either underestimation or overestimation of the number of pregnant women who are at increased risk of fetal malformations and genetic anomalies. Quality control software programs that incorporate the use of a multirule Shewhart chart are designed to detect assay drift. Careful selection of quality control sera for inclusion in analytic assays and appropriate application of a multirule quality control procedure to values that are obtained on these control materials should detect assay drift, regardless of the volume of patients' specimens in the run.
引用
收藏
页码:711 / 714
页数:4
相关论文
共 28 条
[1]   CLINICAL INTERPRETATION OF MATERNAL SERUM ALPHA-FETOPROTEIN CONCENTRATIONS [J].
ADAMS, MJ ;
WINDHAM, GC ;
JAMES, LM ;
GREENBERG, F ;
CLAYTONHOPKINS, JA ;
REIMER, CB ;
OAKLEY, GP .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1984, 148 (03) :241-254
[2]  
[Anonymous], 1971, STAT PRINCIPLES EXPT
[3]  
BEST RG, 1989, MONOGRAPH MED PROFES
[4]  
BOMBARD AT, 1989, MIL MED, V154, P206
[5]   SCREENING FOR FETAL DOWNS-SYNDROME IN PREGNANCY BY MEASURING MATERNAL SERUM ALPHA-FETOPROTEIN LEVELS [J].
DIMAIO, MS ;
BAUMGARTEN, A ;
GREENSTEIN, RM ;
SAAL, HM ;
MAHONEY, MJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1987, 317 (06) :342-346
[6]  
GAMBINO R, 1988, CLIN CHEM NEWS SEP, P5
[7]  
HADDOW JE, 1981, CLIN CHEM, V27, P133
[8]  
HADDOW JE, 1982, HOSP PRAC JAN, P128
[9]  
HULLIN DA, 1988, CLIN CHEM, V34, P1929
[10]   USE OF MATERNAL SERUM ALPHA-FETOPROTEIN MEASUREMENTS TO SCREEN FOR DOWNS-SYNDROME [J].
KNIGHT, GJ ;
PALOMAKI, GE ;
HADDOW, JE .
CLINICAL OBSTETRICS AND GYNECOLOGY, 1988, 31 (02) :306-327