A METHOD FOR COMPUTER-SIMULATION OF ULTRASOUND DOPPLER COLOR FLOW IMAGES .2. SIMULATION RESULTS

被引:15
作者
KERR, AT
HUNT, JW [3 ]
机构
[1] KINGSTON REG CANC CTR,ONTARIO CANC TREATMENT & RES FDN,KINGSTON K7L 2V7,ONTARIO,CANADA
[2] UNIV TORONTO,DEPT MED BIOPHYS,TORONTO M4X 1K9,ONTARIO,CANADA
[3] ONTARIO CANC INST,500 SHERBOURNE ST,TORONTO M4X 1K9,ONTARIO,CANADA
关键词
ULTRASOUND; DOPPLER COLOR FLOW IMAGING; PULSED DOPPLER; COMPUTER SIMULATION;
D O I
10.1016/0301-5629(92)90025-6
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A computational method of simulating Doppler color flow images has been developed. It is based on a point-scattering model of moving blood and surrounding tissue and is capable of treating the entire flow image generation process. Simulated images of parabolic flow dynamics in a cylindrical vessel are presented to show the statistical nature of the map of velocity estimates and to demonstrate the effects of wall filters and different display schemes. Quantitative results of extracted velocity profiles are included and indicate the usefulness of the simulation method for studying the quantitative capabilities of flow imaging.
引用
收藏
页码:873 / 879
页数:7
相关论文
共 13 条
  • [1] DOPPLER ULTRASOUND COLOR FLOW IMAGING IN THE STUDY OF BREAST-CANCER - PRELIMINARY FINDINGS
    ADLER, DD
    CARSON, PL
    RUBIN, JM
    QUINNREID, D
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (06) : 553 - 559
  • [3] COLOR DOPPLER SIGNALS FROM BREAST-TUMORS - WORK IN PROGRESS
    COSGROVE, DO
    BAMBER, JC
    DAVEY, JB
    MCKINNA, JA
    SINNETT, HD
    [J]. RADIOLOGY, 1990, 176 (01) : 175 - 180
  • [4] EVALUATION OF AORTIC DISSECTION BY DOPPLER COLOR FLOW MAPPING
    DAGLI, SV
    NANDA, NC
    ROITMAN, D
    MOOS, S
    HSIUNG, MC
    NATH, PH
    SOTO, B
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1985, 56 (07) : 497 - 498
  • [5] COMPUTER-SIMULATIONS OF SPECKLE IN B-SCAN IMAGES
    FOSTER, DR
    ARDITI, M
    FOSTER, FS
    PATTERSON, MS
    HUNT, JW
    [J]. ULTRASONIC IMAGING, 1983, 5 (04) : 308 - 330
  • [6] REAL-TIME TWO-DIMENSIONAL BLOOD-FLOW IMAGING USING AN AUTO-CORRELATION TECHNIQUE
    KASAI, C
    NAMEKAWA, K
    KOYANO, A
    OMOTO, R
    [J]. IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1985, 32 (03): : 458 - 464
  • [7] A METHOD FOR COMPUTER-SIMULATION OF ULTRASOUND DOPPLER COLOR FLOW IMAGES .1. THEORY AND NUMERICAL-METHOD
    KERR, AT
    HUNT, JW
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1992, 18 (10) : 861 - 872
  • [8] KIMMESMITH C, 1989, IEEE 1989 ULTRASONICS SYMPOSIUM : PROCEEDINGS, VOLS 1 AND 2, P877, DOI 10.1109/ULTSYM.1989.67114
  • [9] CONVENTIONAL AND COLOR DOPPLER IN THE ASSESSMENT OF FETAL AND MATERNAL CIRCULATION
    KURJAK, A
    ALFIREVIC, Z
    MILJAN, M
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1988, 14 (05) : 337 - 354
  • [10] Namekawa K, 1982, ULTRASOUND 82, V2, P203