FLOW-INJECTION DETERMINATION OF ETHANOL BY FIBEROPTIC CHEMILUMINESCENCE MEASUREMENT

被引:50
作者
XIE, XF
SULEIMAN, AA
GUILBAULT, GG
YANG, ZM
SUN, ZA
机构
[1] UNIVERSAL SENSORS INC,METAIRIE,LA 70006
[2] GUIZHOU NORMAL UNIV,DEPT CHEM,GUIYANG 55001,PEOPLES R CHINA
关键词
CHEMILUMINESCENCE; ENZYMATIC METHODS; FLOW INJECTION; ETHANOL; FIBEROPTIC SENSOR; WINES;
D O I
10.1016/0003-2670(92)85059-F
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new approach for the determination of ethanol in beverages is presented. The hydrogen peroxide generated in the enzymatically catalyzed oxidation of ethanol is measured by the luminol chemiluminescence reaction using potassium hexacyanoferrate(III) as a catalyst. Alcohol oxidase is immobilized on aminopropyl glass beads packed in a glass column. The chemiluminescence measurement is made using an optical fiber to transport the luminescence from the flow cell to the detector in conjunction with a flow system. This assay system responds linearly in the ethanol concentration range 3 x 10(-6) - 7.5 x 10(-4) M with a precision of 2.4% and an analysis time of 1.5 min.
引用
收藏
页码:325 / 329
页数:5
相关论文
共 12 条
[1]   FIBER OPTIC SENSORS - RECENT DEVELOPMENTS [J].
ABDELLATIF, MS ;
SULEIMAN, A ;
GUILBAULT, GG ;
DREMEL, BAA ;
SCHMID, RD .
ANALYTICAL LETTERS, 1990, 23 (03) :375-399
[2]   A COLORIMETRIC METHOD FOR THE ENZYMATIC ANALYSIS OF GASES - THE DETERMINATION OF ETHANOL AND FORMALDEHYDE VAPORS USING SOLID ALCOHOL OXIDASE [J].
BARZANA, E ;
KLIBANOV, AM ;
KAREL, M .
ANALYTICAL BIOCHEMISTRY, 1989, 182 (01) :109-115
[3]   ENZYMATIC MEASUREMENT OF ETHANOL OR NAD IN ACID-EXTRACTS OF BIOLOGICAL SAMPLES [J].
CORNELL, NW ;
VEECH, RL .
ANALYTICAL BIOCHEMISTRY, 1983, 132 (02) :418-423
[4]  
HART FL, 1971, MODERN FOOD ANAL
[5]   CHEMILUMINESCENCE FLOW-INJECTION ANALYSIS DETERMINATION OF SUCROSE USING ENZYMATIC CONVERSION AND A MICROPOROUS MEMBRANE FLOW CELL [J].
KOERNER, CA ;
NIEMAN, TA .
ANALYTICAL CHEMISTRY, 1986, 58 (01) :116-119
[6]   GAS-DIFFUSION DILUTION FLOW-INJECTION METHOD FOR THE DETERMINATION OF ETHANOL IN BEVERAGES WITHOUT SAMPLE PRETREATMENT [J].
KUNNECKE, W ;
SCHMID, RD .
ANALYTICA CHIMICA ACTA, 1990, 234 (01) :213-220
[7]   INDIVIDUAL AND SIMULTANEOUS DETERMINATION OF ETHANOL AND ACETALDEHYDE IN WINES BY FLOW-INJECTION ANALYSIS AND IMMOBILIZED ENZYMES [J].
LAZARO, F ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICAL CHEMISTRY, 1987, 59 (14) :1859-1863
[8]   ENZYMATIC ASSAY BY FLOW-INJECTION ANALYSIS WITH DETECTION BY CHEMILUMINESCENCE - DETERMINATION OF GLUCOSE, CREATININE, FREE-CHOLESTEROL AND LACTIC-ACID USING AN INTEGRATED FIA MICROCONDUIT [J].
PETERSSON, BA ;
HANSEN, EH ;
RUZICKA, J .
ANALYTICAL LETTERS, 1986, 19 (5-6) :649-665
[9]  
SWINDLEHURST CA, 1988, ANAL CHIM ACTA, V205, P195
[10]   FIBER-OPTIC BIOSENSOR FOR ETHANOL, BASED ON AN INTERNAL ENZYME CONCEPT [J].
WALTERS, BS ;
NIELSEN, TJ ;
ARNOLD, MA .
TALANTA, 1988, 35 (02) :151-155