STUDIES ON THE EFFECTS OF IMIDAZOLE ON THE PEROXYOXALATE CHEMILUMINESCENCE DETECTION SYSTEM FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:32
|
作者
IMAI, K [1 ]
NISHITANI, A [1 ]
TSUKAMOTO, Y [1 ]
WANG, WH [1 ]
KANDA, S [1 ]
HAYAKAWA, K [1 ]
MIYAZAKI, M [1 ]
机构
[1] KANAZAWA UNIV,FAC PHARMACEUT SCI,KANAZAWA,ISHIKAWA 920,JAPAN
关键词
D O I
10.1002/bmc.1130040305
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The catalytic effect of bases (imidazole, pyridine, Tris and triethylamine) on the peroxyoxalate chemiluminescence (PO‐CL) reaction for high performance liquid chromatography (HPLC) was investigated. Imidazole increased PO‐CL intensity extraordinarily, whereas the other bases (pyridine, Tris and triethylamine) did not. The peak heights of dipyridamole (coronary vasodilator) obtained using the eluents containing buffers were largest at pH 7.0, a few times less at pH 6.0 and pH 5.0, 100 times less at pH 4.0 and a few hundred times less at pH 3.0. The eluents containing buffers at pH 3, 4, 5, 6 or 7 each with imidazole increased the peak heights by a few to ten times as compared with those without imidazole, and those peak heights were within one order of magnitude. On the other hand, the eluent containing buffer at pH 2 did not affect the peak heights with or without imidazole. Bis(4‐nitro‐2‐(3,6,9‐trioxadecyloxycarbonyl)phenyl) oxalate (TDPO) alone and bis(2,4‐dinitrophenyl)oxalate (DNPO) plus TDPO were recommended to be used against eluents containing buffers of pH 5 – 7 and pH 3 – 4, respectively. Dipyridamole and benzydamine hydrochloride (anti‐inflamatory drug) were separated on the ODS column and detected by the present system. The detection limits of dipyridamole and benzydamine hydrochloride were 40 amol and 270 fmol, respectively. Copyright © 1990 John Wiley & Sons, Ltd.
引用
收藏
页码:100 / 104
页数:5
相关论文
共 50 条
  • [21] EVALUATION OF ARYL OXALATES FOR CHEMILUMINESCENCE DETECTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HONDA, K
    MIYAGUCHI, K
    IMAI, K
    ANALYTICA CHIMICA ACTA, 1985, 177 : 103 - 110
  • [22] NEW CHEMILUMINESCENT DERIVATIZING AGENT FOR THE ANALYSIS OF ALDEHYDES AND KETONES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PEROXYOXALATE CHEMILUMINESCENCE
    MANN, B
    GRAYESKI, ML
    JOURNAL OF CHROMATOGRAPHY, 1987, 386 : 149 - 158
  • [23] Sensitive detection of near-infrared fluorescent dyes using high-performance liquid chromatography with peroxyoxalate chemiluminescence detection system
    Kimoto, K
    Gohda, R
    Murayama, K
    Santa, T
    Fukushima, T
    Homma, H
    Imai, K
    BIOMEDICAL CHROMATOGRAPHY, 1996, 10 (04) : 189 - 190
  • [24] High performance liquid chromatography with peroxyoxalate chemiluminescence detection of synthetic peptide, ebiratide
    Hamachi, Y
    Nakashima, K
    Akiyama, S
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1997, 20 (15) : 2377 - 2387
  • [25] CHEMILUMINESCENCE - HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PHOSPHATIDYLCHOLINE HYDROPEROXIDE
    MIYAZAWA, T
    YASUDA, K
    FUJIMOTO, K
    ANALYTICAL LETTERS, 1987, 20 (06) : 915 - 925
  • [26] Determination of aromatic compounds by high-performance liquid chromatography with on-line photoreactor and peroxyoxalate chemiluminescence detection
    Ihara, Ayuko
    Kishikawa, Naoya
    Wada, Mitsuhiro
    Ohba, Yoshihito
    Nakashima, Kenichiro
    Kuroda, Naotaka
    LUMINESCENCE, 2007, 22 (06) : 567 - 574
  • [27] SENSITIVE ASSAY SYSTEM FOR BILE-ACIDS AND STEROIDS HAVING HYDROXYL-GROUPS UTILIZING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PEROXYOXALATE CHEMILUMINESCENCE DETECTION
    HIGASHIDATE, S
    HIBI, K
    SENDA, M
    KANDA, S
    IMAI, K
    JOURNAL OF CHROMATOGRAPHY, 1990, 515 : 577 - 584
  • [28] ZERO-DEAD-VOLUME PEROXYOXALATE CHEMILUMINESCENCE DETECTION IN LIQUID-CHROMATOGRAPHY
    CEPAS, J
    SILVA, M
    PEREZBENDITO, D
    ANALYTICAL CHEMISTRY, 1995, 67 (23) : 4376 - 4379
  • [29] Determination of amikacin in body fluid by high-performance liquid-chromatography with chemiluminescence detection
    Serrano, Juan Manuel
    Silva, Manuel
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 843 (01): : 20 - 24
  • [30] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CHEMILUMINESCENCE DETECTION OF METHAMPHETAMINE AND AMPHETAMINE IN HUMAN URINE
    NAKASHIMA, K
    SUETSUGU, K
    YOSHIDA, K
    IMAI, K
    AKIYAMA, S
    ANALYTICAL SCIENCES, 1991, 7 (05) : 815 - 816