STABILIZED BILAYER-LIPID MEMBRANES FOR FLOW-THROUGH EXPERIMENTS

被引:49
|
作者
NIKOLELIS, DP [1 ]
SIONTOROU, CG [1 ]
ANDREOU, VG [1 ]
KRULL, UJ [1 ]
机构
[1] UNIV TORONTO,DEPT CHEM,CHEM SENSORS GRP,MISSISSAUGA,ON L5L 1C6,CANADA
关键词
BIOSENSORS; BILAYER LIPID MEMBRANES; STABILIZATION; FLOW-THROUGH INJECTION; DIFFERENTIAL SCANNING CALORIMETRY;
D O I
10.1002/elan.1140070605
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work reports a technique for the stabilization of solventless bilayer lipid membranes (BLMs), and the use of stabilized BLMs as flow detectors. Microporous filters composed of glass fibers, polytetrafluoroethylene (PTFE) and polycarbonate (nominal pore sizes from 1 to 5 mu m) can serve as interfaces that separate two solution compartments. The micropores in the filter media can act as supports for formation and stabilization of BLMs. One of the solution compartments is used to cast lipid films on the filters, while a carrier electrolyte solution concurrently hows through the opposing compartment. Optimization of the how cell design, and the chemical composition and methods for preparation of stabilized BLMs, are described. Lipid membranes composed of mixtures of phosphatidyl choline and phosphatidic acid could respond rapidly to pH alterations of the carrier electrolyte solution. Signals would reproducibly appear within a few seconds following the injection of an electrolyte of different pH than the carrier. Signals took the form of a single ion current transient with magnitude of tens of picoamperes (pA) and a duration of seconds. The mechanism of signal generation is explored by differential scanning calorimetry. The results show that a phase transition within a lipid membrane can be triggered by pH alterations of the electrolyte solution. Stabilized BLMs which provide artificial ion gating events hold prospects for chemical sensing of process streams.
引用
收藏
页码:531 / 536
页数:6
相关论文
共 50 条
  • [31] ION TRANSFER THROUGH A LIQUID MEMBRANE OR A BILAYER-LIPID MEMBRANE IN THE PRESENCE OF SUFFICIENT ELECTROLYTES
    SHIRAI, O
    KIHARA, S
    YOSHIDA, Y
    MATSUI, M
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 389 (1-2) : 61 - 70
  • [32] EFFECT OF ULTRASOUND ON THE PH PROFILES IN THE UNSTIRRED LAYERS NEAR PLANAR BILAYER-LIPID MEMBRANES MEASURED BY MICROELECTRODES
    POHL, P
    ANTONENKO, YN
    ROSENFELD, E
    BIOCHIMICA ET BIOPHYSICA ACTA, 1993, 1152 (01) : 155 - 160
  • [33] HARDWARE FOR MEASURING FLOW-THROUGH MICROPOROUS MEMBRANES
    ARENAS, A
    VICTORIA, L
    MOLINA, C
    IBANEZ, JA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (11): : 5343 - 5347
  • [34] HEMATOPORPHYRIN DIMETHYL ETHER TRANSPORT ACROSS BILAYER-LIPID MEMBRANE
    STOZHKOVA, IN
    CHERNY, VV
    SOKOLOV, VS
    BIOLOGICHESKIE MEMBRANY, 1995, 12 (02): : 200 - 207
  • [35] Interpreting neutron spin echo experiments on lipid bilayer membranes
    Brown, Frank L.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 243
  • [36] BARRIER MODEL FOR CURRENT FLOW IN LIPID BILAYER MEMBRANES
    HALL, JE
    MEAD, CA
    SZABO, G
    JOURNAL OF MEMBRANE BIOLOGY, 1973, 11 (01): : 75 - 97
  • [37] Permeability of nitric oxide through lipid bilayer membranes
    Subczynski, WK
    Lomnicka, M
    Hyde, JS
    FREE RADICAL RESEARCH, 1996, 24 (05) : 343 - 349
  • [38] A MICROMACHINED POLYMIDE APERTURE FOR STABLE BILAYER-LIPID MEMBRANE (BLMS)
    ERAY, M
    DOGAN, NS
    LIU, LJ
    KOCH, AR
    MOFFETT, DF
    SILBER, M
    VANWIE, BJ
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1993, 40 (11) : 2137 - 2138
  • [39] Characterization of flow-through micropores in MFI membranes by permporometry
    Korelskiy, Danil
    Grahn, Mattias
    Mouzon, Johanne
    Hedlund, Jonas
    JOURNAL OF MEMBRANE SCIENCE, 2012, 417 : 183 - 192
  • [40] Precipitation of silica minerals in hydrothermal flow-through experiments
    Saishu, H.
    Okamoto, A.
    Tsuchiya, N.
    WATER-ROCK INTERACTION (WRI-13), 2010, : 669 - 672