EFFECT OF LOW FRESH GAS-FLOW RATES ON INSPIRED GAS-COMPOSITION IN A CIRCLE ABSORBER SYSTEM

被引:8
作者
GREGORINI, P
机构
[1] Department of Anesthesia, C.A. Pizzardi Maggiore Hospital, Bologna
关键词
ANESTHETIC TECHNIQUES; LOW-FLOW ANESTHESIA; ANESTHETIC GAS; NITROUS OXIDE; OXYGEN; INSPIRED FRACTION OF;
D O I
10.1016/0952-8180(92)90214-L
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Study Objective: To determine the effects of fresh gas flow on inspired gas composition during low-flow anesthesia. Design: Randomized trial with 2-hour observation periods in patients assigned to one of three groups. Setting: Inpatient surgery clinic at a medical center. Patients: Thirty-six patients undergoing abdominal surgery with low-flow anesthesia. Interventions: Fresh gas flow was given at a starting rate of 5 L/min for 6 minutes. Thereafter, the fresh gas flow setting was nitrous oxide (N2O) 1 L/min and oxygen (O2) 0.6 L/min (Group 1), N2O 0.5 L/min and 0, 0.5 L/min (Group 2), and with a moderate surplus of N2O and 02 with respect to the patient's 02 Consumption (Group 3). Measurements and Main Results: The inspired 02 concentration (FIO2) was measured using a paramagnetic technique, and N2O levels were measured with infrared sensors; the inspired nitrogen concentration (FIN2) was calculated by the following formula: FIN2 = 1 - FIO2 - FIN2O, where FIN2O is the inspired N2O concentration. After 1 hour of anesthesia, FIO2 was significantly lower in Group 1 than in Groups 2 and 3 (p < 0.01), and FIN2 was significantly higher in Groups 2 and 3 than in Group 1 (p < 0.01). After 2 hours of anesthesia, FIN2 returned to normal in Group 2 but continued to increase in Group 3. FIN2O was close to 0. 7 % only in Group 1. Conclusions: The same initial period of denitrogenation is not adequate to denitrogenate the circle system in all cases. The lower the fresh gas flow, the longer the initial period of denitrogenation should be. Various levels of fresh gas flow for low-flow anesthesia have been suggested, but none guarantees adequate control of inspired gas composition unless flowmeters are continuously adjusted.
引用
收藏
页码:439 / 443
页数:5
相关论文
共 13 条
[1]  
Conway, Closed and low flow systems. Theoretical considerations, Acta Anaesthesiol Belg, 35, pp. 257-263, (1984)
[2]  
Holmes, Spears, Very-nearly-closed-circuit anaesthesia. A computer analysis, Anaesthesia, 32, pp. 846-851, (1977)
[3]  
Forbes, Inspired oxygen concentrations in semiclosed circle absorber circuits with low flows of nitrous oxide and oxygen, Br j Anaesth, 44, pp. 1081-1084, (1972)
[4]  
Barton, Nunn, Totally closed circuit nitrous oxide/oxygen anaesthesia, Br J Anaesth, 47, pp. 350-357, (1975)
[5]  
Morita, Latta, Hambro, Snider, Accumulation of methane, acetone, and nitrogen in the inspired gas during closed-circuit anesthesia, Anesth Analg, 64, pp. 343-347, (1985)
[6]  
Bengtson, Sonander, Stenqvist, Gaseous homeostasis during low-flow anaesthesia, Acta Anaesthesiol Scand, 32, pp. 516-521, (1988)
[7]  
Merilainen, A fast differential paramagnetic O<sub>2</sub>-sensor, International Journal of Clinical Monitoring and Computing, 5, pp. 187-195, (1988)
[8]  
Sharp, Trudell, Cohen, Volatile metabolites and decomposition products of halothane in man, Anesthesiology, 50, pp. 2-8, (1979)
[9]  
Aldrete, A practical perspective on low, minimal and closed system anesthesia, Acta Anaesthesiol Belg, 35, pp. 251-256, (1984)
[10]  
Conway, Gaseous homeostasis and the circle system. Validation of a model, Br J Anaesth, 58, pp. 337-344, (1986)