FLOW CAPACITIES OF ARTERIAL GRAFTS FOR CORONARY-ARTERY BYPASS-GRAFTING

被引:34
作者
KAWASUJI, M [1 ]
TEDORIYA, T [1 ]
TAKEMURA, H [1 ]
SAKAKIBARA, N [1 ]
TAKI, J [1 ]
WATANABE, Y [1 ]
机构
[1] KANAZAWA UNIV,SCH MED,DEPT NUCL MED,KANAZAWA,ISHIKAWA 920,JAPAN
关键词
D O I
10.1016/0003-4975(93)90363-M
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The flow capacities of arterial and saphenous vein grafts in 100 patients who had coronary artery bypass grafting were compared under exercise conditions by continuous ventricular function monitoring, which records serial beat-to-beat radionuclide data and calculates left ventricular ejection fractions every 20 seconds. Ejection fraction profiles during graded bicycle exercise were divided into four types. In type A, the ejection fraction continued to increase. In type B, the ejection fraction initially increased, but decreased during the late exercise stage. In type C, the ejection fraction did not change. In type D, the ejection fraction continued to decrease throughout exercise. A decrease in ejection fraction, observed in type B or D, is an early indicator of myocardial ischemia. Before operation, 10 patients showed type A, 30 type B, 11 type C, and 49 type D responses. After operation, 68 patients showed type A, 21 type B, and 11 type C responses. Patients were divided into three groups according the type of bypass graft. Group 1 included 21 patients with two arterial grafts and vein grafts; group 2, 61 patients with an internal thoracic artery graft and vein grafts; group 3, 18 patients with only vein grafts. All of the grafts were patent on angiography. Eight patients (38%) in group 1 and 13 (21%) in group 2 showed a postoperative type B response, but none of the patients in group 3 had a postoperative type B response (p < 0.02). Seven of 8 patients in group 1 with postoperative type B responses had only arterial grafts to the left-side coronary arteries. It was suggested that flow through arterial grafts was adequate for moderate exercise but inadequate for maximal exercise, as evidenced by the group of patients with type B ejection fraction response on graded bicycle exercise.
引用
收藏
页码:957 / 962
页数:6
相关论文
共 19 条
[1]  
BARNER HB, 1987, J THORAC CARDIOV SUR, V93, P316
[2]   SENSITIVITY, SPECIFICITY AND PREDICTIVE ACCURACY OF RADIONUCLIDE CINEANGIOGRAPHY DURING EXERCISE IN PATIENTS WITH CORONARY-ARTERY DISEASE - COMPARISON WITH EXERCISE ELECTROCARDIOGRAPHY [J].
BORER, JS ;
KENT, KM ;
BACHARACH, SL ;
GREEN, MV ;
ROSING, DR ;
SEIDES, SF ;
EPSTEIN, SE ;
JOHNSTON, GS .
CIRCULATION, 1979, 60 (03) :572-580
[3]   COMPARISON OF REST AND EXERCISE RADIONUCLIDE ANGIOCARDIOGRAPHY AND EXERCISE TREADMILL TESTING FOR DIAGNOSIS OF ANATOMICALLY EXTENSIVE CORONARY-ARTERY DISEASE [J].
CAMPOS, CT ;
CHU, HW ;
DAGOSTINO, HJ ;
JONES, RH .
CIRCULATION, 1983, 67 (06) :1204-1210
[4]   COMPARATIVE HEMODYNAMIC PROPERTIES OF VEIN AND MAMMARY ARTERY IN CORONARY-BYPASS OPERATIONS [J].
FLEMMA, RJ ;
SINGH, HM ;
TECTOR, AJ ;
LEPLEY, D ;
FRAZIER, BL .
ANNALS OF THORACIC SURGERY, 1975, 20 (06) :619-627
[5]   COMPARATIVE-STUDY OF POSTOPERATIVE FLOW IN SAPHENOUS-VEIN AND INTERNAL MAMMARY ARTERY BYPASS GRAFTS [J].
HAMBY, RI ;
AINTABLIAN, A ;
WISOFF, BG ;
HARTSTEIN, ML .
AMERICAN HEART JOURNAL, 1977, 93 (03) :306-315
[6]  
HOLMBERG S, 1971, ACTA MED SCAND, V190, P465
[7]  
JONES EL, 1989, J THORAC CARDIOV SUR, V98, P902
[8]   ACCURACY OF DIAGNOSIS OF CORONARY-ARTERY DISEASE BY RADIONUCLIDE MEASUREMENT OF LEFT-VENTRICULAR FUNCTION DURING REST AND EXERCISE [J].
JONES, RH ;
MCEWAN, P ;
NEWMAN, GE ;
PORT, S ;
RERYCH, SK ;
SCHOLZ, PM ;
UPTON, MT ;
PETER, CA ;
AUSTIN, EH ;
LEONG, KH ;
GIBBONS, RJ ;
COBB, FR ;
COLEMAN, RE ;
SABISTON, DC .
CIRCULATION, 1981, 64 (03) :586-601
[9]  
KAWASUJI M, 1990, J THORAC CARDIOV SUR, V99, P696
[10]   SILENT LEFT-VENTRICULAR DYSFUNCTION DURING EXERCISE AFTER CORONARY-ARTERY BYPASS-SURGERY [J].
KAWASUJI, M ;
TEDORIYA, T ;
SAKAKIBARA, N ;
TAKAHASHI, M ;
TAKI, J ;
WATANABE, Y .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1991, 5 (12) :618-622