摘要
The Kelvin probe, used to measure changes in work function (wf), has proved particularly useful as a UHV surface analysis technique, having applications in the study of thin films, adsorption kinetics, surface photovoltage spectroscopy, surface topographies, etc. However the Kelvin circuit is plagued by noise problems, which are considerably enhanced by long connecting wires and the nonideal UHV environment. Careful shielding is essential in order to improve the signal-to-noise (S/N) ratio, especially at backing potentials close to the null condition. Although lock-in-amplifer (LIA) based automatic compensation systems are available they operate on low signal levels and are prone to electromagnetic pickup from the driving element and mechanical instabilities of the vibrating capacitor. We discuss the general noise spectrum and describe an alternative "off-null" approach utilizing a data-acquisition-system (DAS) based measuring system that features an active suspension system (ASS), automatic set-up, and software elimination of driver talkover. This system has applications where very high resolution ( < 0.1 meV) is required, or if low S/N ratios caused by reduced probe dimensions or a high noise background would otherwise prejudice the measurement.
引用
收藏
页码:1326 / 1332
页数:7
相关论文
共 51 条
[1]   A DIRECT COMPARISON OF THE KELVIN AND ELECTRON BEAM METHODS OF CONTACT POTENTIAL MEASUREMENT [J].
ANDERSON, PA .
PHYSICAL REVIEW, 1952, 88 (03) :655-658
[2]  
BACZYNSKI J, 1988, REV SCI INSTRUM, V59, P2473
[3]   INTEGRATED AUTOMATIC MODULAR MEASURING SYSTEM [J].
BAIKIE, ID ;
VANDERWERF, KO ;
HANEKAMP, LJ .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (09) :2075-2078
[4]   AUTOMATIC KELVIN PROBE COMPATIBLE WITH ULTRAHIGH-VACUUM [J].
BAIKIE, ID ;
VANDERWERF, KO ;
OERBEKKE, H ;
BROEZE, J ;
VANSILFHOUT, A .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (05) :930-934
[5]  
BAIKIE ID, IN PRESS REV SCI INS
[6]  
BAIKIE ID, 1988, THESIS U TWENTE
[7]   MICRO KELVIN PROBE FOR LOCAL WORK-FUNCTION MEASUREMENTS [J].
BAUMGARTNER, H ;
LIESS, HD .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (05) :802-805
[8]   PIEZOELECTRIC DRIVEN KELVIN PROBE FOR CONTACT POTENTIAL DIFFERENCE STUDIES [J].
BESOCKE, K ;
BERGER, S .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1976, 47 (07) :840-842
[9]   A 2 FREQUENCY VIBRATING CAPACITOR METHOD FOR CONTACT POTENTIAL DIFFERENCE MEASURMENTS [J].
BLOTT, BH ;
LEE, TJ .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1969, 2 (09) :785-&
[10]   THE KELVIN PROBE METHOD FOR WORK FUNCTION TOPOGRAPHIES - TECHNICAL PROBLEMS AND SOLUTIONS [J].
BONNET, J ;
SOONCKINDT, L ;
LASSABATERE, L .
VACUUM, 1984, 34 (07) :693-698