A comparison of non-invasive versus invasive methods of haemoglobin estimation in patients undergoing intracranial surgery

被引:7
作者
Khanna, Puneet [1 ]
Rajagopalan, Vanitha [1 ]
Singh, Gyaninder [2 ]
Prabhakar, Hemanshu [2 ]
机构
[1] All India Inst Med Sci, Dept Anaesthesiol, New Delhi, India
[2] All India Inst Med Sci, Dept Neuroanaesthesiol, New Delhi, India
关键词
comparison; haemoglobin estimation; intracranial; invasive; monitoring; non-invasive; surgery;
D O I
10.1080/22201173.2014.936749
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Until recently, invasive monitoring techniques were the only ones available for the estimation of haemoglobin (Hb) in the blood. However, following the introduction of a new non-invasive monitor, Hb concentration could be non-invasively and continuously monitored. It allows immediate and ongoing Hb changes to be displayed during surgery, which may aid in the rapid detection of clinically significant blood loss. To test the accuracy of this non-invasive monitor, we compared Hb levels obtained using standard invasive techniques (laboratory and arterial blood gas machine analysis) with those derived from a non-invasive monitor. Method: Thirty patients undergoing various intracranial surgeries were enrolled in the study. Blood samples were withdrawn for Hb estimation from the laboratory [total haemoglobin mass (tHb)] and arterial blood gas (ABG) machine (aHb), using automated Hb analyser techniques randomly at any point during the surgery. At the same time, the Hb values displayed on the non-invasive monitor [Radical-7 (R) Pulse Co-oximeter (SpHb (R))], together with the perfusion index (PI), were also noted. Results: The perfusion index (PI) was less than 1.4 in eight patients. The obtained Hb values were unreliable, as per the manufacturer's recommendations. Statistical analysis showed poor correlation between the invasive and non-invasive techniques of Hb estimation in the remaining 22 patients. Conclusion: Non-invasive Hb monitoring (SpHb (R)) may not have sufficient accuracy to minimise the need for invasive Hb monitoring. However, it may allow continuous monitoring of Hb and could guide clinicians as to the need for invasive monitoring.
引用
收藏
页码:160 / 163
页数:4
相关论文
共 10 条
[1]  
Barr SJ, 2010, 2010 ANN M AM SOC AN
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Non-invasive measurement of hemoglobin during cesarean hysterectomy: a case series [J].
Butwick, A. J. ;
Hilton, G. ;
Riley, E. T. ;
Carvalho, B. .
INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2011, 20 (03) :240-245
[4]  
Carstensen B., 2008, INT J BIOSTAT, V4, DOI DOI 10.2202/1557-4679.1107
[5]   Instability in non-invasive haemoglobin measurement: a possible influence of oxygen administration [J].
Gayat, E. ;
Bodin, A. ;
Fischler, M. .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2011, 55 (07) :902-902
[6]   Performance Evaluation of a Noninvasive Hemoglobin Monitoring Device [J].
Gayat, Etienne ;
Bodin, Antoine ;
Sportiello, Caroline ;
Boisson, Mireille ;
Dreyfus, Jean-Francois ;
Mathieu, Emmanuel ;
Fischler, Marc .
ANNALS OF EMERGENCY MEDICINE, 2011, 57 (04) :330-333
[7]   Non-invasive monitoring of blood haemoglobin for analysis of fluid volume kinetics [J].
Hahn, R. G. ;
Li, Y. ;
Zdolsek, J. .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2010, 54 (10) :1233-1240
[8]   The Accuracy of Noninvasive and Continuous Total Hemoglobin Measurement by Pulse CO-Oximetry in Human Subjects Undergoing Hemodilution [J].
Macknet, Mark R. ;
Allard, Martin ;
Applegate, Richard L. ;
Rook, James .
ANESTHESIA AND ANALGESIA, 2010, 111 (06) :1424-1426
[9]   A Comparison of Three Methods of Hemoglobin Monitoring in Patients Undergoing Spine Surgery [J].
Miller, Ronald D. ;
Ward, Theresa A. ;
Shiboski, Stephen C. ;
Cohen, Neal H. .
ANESTHESIA AND ANALGESIA, 2011, 112 (04) :858-863
[10]  
Richard KM, 2010, 2010 ANN M AM SOC AN