BLOOD-FLOW IN THE HUMAN ACHILLES-TENDON ASSESSED BY LASER-DOPPLER FLOWMETRY

被引:90
作者
ASTROM, M
WESTLIN, N
机构
[1] Section of Sports Medicine, Department of Orthopaedics, Malmö General Hospital, Lund University, Malmö
关键词
D O I
10.1002/jor.1100120214
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study evaluated microvascular perfusion in the human Achilles tendon by laser Doppler flowmetry (LDF) at rest, during vascular occlusion, and during passive stretch and isometric contraction of the triceps surae. In 40 healthy volunteers, an intratendinous needle probe was introduced 5 mm above the distal insertion, at the midportion, and at the musculotendinous junction of both legs. Values were obtained at rest and during temporary vascular occlusion. Twenty-eight of the subjects also were assessed during physical provocation by passive stretch and isometric contraction of the triceps surae. Blood flow was significantly lower near the calcaneal insertion but otherwise was distributed evenly in the tendon. The output signal showed a pulsatile variation synchronous with heart activity, and temporary vascular occlusion always caused a pronounced reduction in LDF values. Passive stretch and isometric contraction induced a progressive decline in LDF values as tension increased. Hyperemia often appeared after contraction. Tendon blood flow was higher in women and decreased with increasing age.
引用
收藏
页码:246 / 252
页数:7
相关论文
共 27 条
[1]   TENDON BLOOD-FLOW ASSESSED BY LASER DOPPLER FLOWMETRY [J].
ASTROM, M ;
SVENSSON, H .
SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 1991, 25 (03) :213-215
[2]  
CASPARY L, 1988, INT J MICROCIRC, V7, P367
[3]   DIRECT ASSESSMENT OF SYNOVIAL BLOOD-FLOW AND ITS RELATION TO INDUCED HYDROSTATIC-PRESSURE CHANGES [J].
GEBOREK, P ;
FORSLIND, K ;
WOLLHEIM, FA .
ANNALS OF THE RHEUMATIC DISEASES, 1989, 48 (04) :281-286
[4]   ESTIMATION OF AMPUTATION LEVEL WITH A LASER DOPPLER FLOWMETER [J].
GEBUHR, P ;
JORGENSEN, JP ;
VOLLMERLARSEN, B ;
NIELSEN, SL ;
ALSBJORN, B .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1989, 71 (03) :514-517
[5]  
HASTAD K, 1959, Acta Chir Scand, V116, P251
[6]   BLOOD-FLOW AND CLEARANCE IN TENDONS - STUDIES WITH DOGS [J].
HOOPER, G ;
DAVIES, R ;
TOTHILL, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1984, 66 (03) :441-443
[7]   NUTRIENT PATHWAYS TO EXTENSOR TENDONS OF PRIMATES [J].
MANSKE, PR ;
OGATA, K ;
LESKER, PA .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1985, 10B (01) :8-10
[8]   NUTRIENT PATHWAYS OF FLEXOR TENDONS IN PRIMATES [J].
MANSKE, PR ;
LESKER, PA .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1982, 7 (05) :436-444
[9]   THE RELATIONSHIP OF VASCULARITY AND WATER-CONTENT TO TENSILE-STRENGTH IN A PATELLAR TENDON REPLACEMENT OF THE ANTERIOR CRUCIATE IN DOGS [J].
MCFARLAND, EG ;
MORREY, BF ;
AN, KN ;
WOOD, MB .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1986, 14 (06) :436-448
[10]   COMPARISON OF XE-133 CLEARANCE AND LASER DOPPLER FLOWMETRY IN ASSESSMENT OF BLOOD-FLOW CHANGES IN HUMAN MASSETER MUSCLE INDUCED BY ISOMETRIC CONTRACTION [J].
MONTEIRO, AA ;
SVENSSON, H ;
BORNMYR, S ;
ARBORELIUS, M ;
KOPP, S .
ARCHIVES OF ORAL BIOLOGY, 1989, 34 (10) :779-786