INVIVO X-RAY-FLUORESCENCE OF LEAD IN BONE

被引:40
作者
TODD, AC
MCNEILL, FE
FOWLER, BA
机构
[1] University of Maryland at Baltimore, Baltimore, MD 21201, 660 West Redwood Street
关键词
D O I
10.1016/S0013-9351(05)80039-8
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The in vivo measurement of lead in bone by K X-ray fluorescence (K XRF) is becoming an increasingly widely utilized technique for assessing long-term lead dosimetry. Several groups have already reported the development of in vivo measurement systems, the majority adopting the 109Cd/backscatter K XRF technique because of its substantial advantages in terms of a robust measurement, lower detection limit (compared with 57Co/90°), absence of the need for sedation of younger subjects, and lower effective (radiation) dose when calculated according to the most recent guidelines. The advantages of the 109Cd system are primarily a consequence of the physics principles of the technique. The apparatus of each XRF technique is transportable, facilitating easy establishment of mobile laboratory facilities. More research is needed to substantiate claims made for particular XRF technologies, but both L and K XRF techniques provide the possibility of improved understanding of the body's handling of the ubiquitous toxin lead. © 1992 Academic Press, Inc.
引用
收藏
页码:326 / 335
页数:10
相关论文
共 50 条
  • [31] IN-VIVO X-RAY-FLUORESCENCE MEASUREMENTS OF CADMIUM AND LEAD
    NILSSON, U
    SKERFVING, S
    [J]. SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1993, 19 : 54 - 58
  • [32] PORTABLE X-RAY-FLUORESCENCE INSTRUMENTS FOR ANALYSIS OF LEAD IN PAINTS
    KAPLAN, EH
    LILLEY, MD
    SCHAEFER, RF
    CADE, B
    DESAI, A
    PADVA, A
    ORBACH, HG
    [J]. PUBLIC HEALTH REPORTS, 1975, 90 (03) : 223 - 230
  • [33] DETERMINATION OF BISMUTH IN LEAD CONCENTRATES BY EXTRACTION AND X-RAY-FLUORESCENCE
    REVENKO, AG
    VOLODIN, SA
    UVAROV, AI
    [J]. INDUSTRIAL LABORATORY, 1991, 57 (04): : 393 - 394
  • [34] XE-133 FOR THE X-RAY-FLUORESCENCE ASSESSMENT OF GOLD INVIVO
    SCOTT, J
    LILLICRAP, S
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (07) : 859 - 864
  • [35] AN X-RAY-FLUORESCENCE TECHNIQUE TO MEASURE THE MERCURY BURDEN OF DENTISTS INVIVO
    BLOCH, P
    SHAPIRO, IM
    [J]. MEDICAL PHYSICS, 1981, 8 (03) : 308 - 311
  • [36] X-RAY-FLUORESCENCE OF (IRREGULARLY SHAPED) BONE SAMPLE MATERIALS
    TOMIC, S
    KRMPOTICNEMANIC, J
    VALKOVIC, V
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1986, 18 (01) : 71 - 76
  • [37] DICHROISM IN X-RAY-FLUORESCENCE
    STRANGE, P
    HAGUE, CF
    MARIOT, JM
    DURHAM, PJ
    GYORFFY, BL
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1993, 32 : 302 - 304
  • [38] DICHROIC X-RAY-FLUORESCENCE
    STRANGE, P
    DURHAM, PJ
    GYORFFY, BL
    [J]. PHYSICAL REVIEW LETTERS, 1991, 67 (25) : 3590 - 3593
  • [39] X-RAY-FLUORESCENCE ANALYSIS
    JENKINS, R
    [J]. ANALYTICAL CHEMISTRY, 1984, 56 (09) : 1099 - +
  • [40] COMPUTERS AND X-RAY-FLUORESCENCE
    KARLSSON, A
    [J]. JKA-JERNKONTORETS ANNALER, 1984, 168 (06): : 42 - 42