INVIVO X-RAY-FLUORESCENCE OF LEAD IN BONE

被引:40
作者
TODD, AC
MCNEILL, FE
FOWLER, BA
机构
[1] University of Maryland at Baltimore, Baltimore, MD 21201, 660 West Redwood Street
关键词
D O I
10.1016/S0013-9351(05)80039-8
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The in vivo measurement of lead in bone by K X-ray fluorescence (K XRF) is becoming an increasingly widely utilized technique for assessing long-term lead dosimetry. Several groups have already reported the development of in vivo measurement systems, the majority adopting the 109Cd/backscatter K XRF technique because of its substantial advantages in terms of a robust measurement, lower detection limit (compared with 57Co/90°), absence of the need for sedation of younger subjects, and lower effective (radiation) dose when calculated according to the most recent guidelines. The advantages of the 109Cd system are primarily a consequence of the physics principles of the technique. The apparatus of each XRF technique is transportable, facilitating easy establishment of mobile laboratory facilities. More research is needed to substantiate claims made for particular XRF technologies, but both L and K XRF techniques provide the possibility of improved understanding of the body's handling of the ubiquitous toxin lead. © 1992 Academic Press, Inc.
引用
收藏
页码:326 / 335
页数:10
相关论文
共 50 条
  • [21] INVIVO X-RAY-FLUORESCENCE MEASUREMENTS AS A DIAGNOSTIC TOOL
    LOEWINGER, E
    KALMAN, ZH
    WEINREB, A
    ZEIMER, R
    BELKIN, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (01) : 142 - 142
  • [22] DETECTION OF LEAD IN PAINT USING X-RAY-FLUORESCENCE
    GRODZINS, L
    PARSONS, C
    SACKETT, D
    SHEFSKY, S
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 207 : 72 - NUCL
  • [23] THE REPRODUCIBILITY OF CD-109-BASED X-RAY-FLUORESCENCE MEASUREMENTS OF BONE LEAD
    GORDON, CL
    WEBBER, CE
    CHETTLE, DR
    ENVIRONMENTAL HEALTH PERSPECTIVES, 1994, 102 (08) : 690 - 694
  • [24] X-RAY-FLUORESCENCE ANALYSIS OF SINTERS FOR LEAD SMELTING
    POTTKAMP, F
    JANSSEN, A
    HAASE, W
    PIPPERR, E
    HILDEBRAND, K
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1982, 310 (1-2): : 21 - 29
  • [25] INVIVO X-RAY-FLUORESCENCE OF LEAD IN BONE USING K X-RAY-EXCITATION WITH CD-109 SOURCES - RADIATION-DOSIMETRY STUDIES
    TODD, AC
    MCNEILL, FE
    PALETHORPE, JE
    PEACH, DE
    CHETTLE, DR
    TOBIN, MJ
    STROSKO, SJ
    ROSEN, JC
    ENVIRONMENTAL RESEARCH, 1992, 57 (02) : 117 - 132
  • [26] X-RAY-FLUORESCENCE TECHNIQUE FOR ANALYSIS OF LEAD IN GASOLINE
    LARSON, JA
    SHORT, MA
    BONFIGLI.S
    ALLIE, W
    X-RAY SPECTROMETRY, 1974, 3 (03) : 125 - 129
  • [27] CADMIUM IN MAN MEASURED INVIVO BY X-RAY-FLUORESCENCE ANALYSIS
    AHLGREN, L
    MATTSSON, S
    PHYSICS IN MEDICINE AND BIOLOGY, 1981, 26 (01) : 19 - 26
  • [28] DETERMINATION OF LEAD IN ATMOSPHERIC DUST BY X-RAY-FLUORESCENCE SPECTROMETRY
    GALLOO, JC
    GUILLERMO, R
    ANALUSIS, 1989, 17 (10) : 576 - 580
  • [29] DETERMINATION OF LEAD IN PLANT ASH BY X-RAY-FLUORESCENCE SPECTROMETRY
    DIETZ, ML
    TACKETT, SL
    ANALYTICAL CHEMISTRY, 1983, 55 (04) : 812 - 813
  • [30] IN-VIVO X-RAY-FLUORESCENCE MEASUREMENTS OF CADMIUM AND LEAD
    NILSSON, U
    SKERFVING, S
    SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1993, 19 : 54 - 58