INVESTIGATION OF THE CONVOLUTION METHOD FOR POLYENERGETIC SPECTRA

被引:115
作者
PAPANIKOLAOU, N
MACKIE, TR
MEGERWELLS, C
GEHRING, M
RECKWERDT, P
机构
[1] Department of Medical Physics, University of Wisconsin, Madison
关键词
RADIOTHERAPY; PHOTON DOSIMETRY; CONVOLUTION; MONTE-CARLO; CONVOLUTION KERNEL; BEAM SPECTRUM; HOMOGENEOUS PHANTOM;
D O I
10.1118/1.597154
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The distribution of absolute dose per unit fluence from polyenergetic photon beams impinging upon a water phantom was calculated using two convolution approaches that properly account for beam hardening effects. Dose deposition kernels calculated previously using the EGS4 Monte Carlo code are convolved with the primary terma to give the dose for monoenergetic photon beams of energies ranging from 100 kev to 50 MeV. A polyenergetic dose distribution is composed of separately calculated monoenergetic components, which are appropriately weighted with the fluence spectrum to yield the polyenergetic dose distribution. Alternatively, a single convolution for the polyenergetic beam is considered, where a composite polyenergetic kernel is convolved with the respective polyenergetic terma. The effects of the polyenergetic kernel variance due to beam hardening as well as the effect of tilting the kernels for a diverging beam geometry were also examined. The depth dose data produced using the two proposed methods were compared with measured data and Monte Carlo simulations and showed good agreement.
引用
收藏
页码:1327 / 1336
页数:10
相关论文
共 12 条
[1]   COLLAPSED CONE CONVOLUTION OF RADIANT ENERGY FOR PHOTON DOSE CALCULATION IN HETEROGENEOUS MEDIA [J].
AHNESJO, A .
MEDICAL PHYSICS, 1989, 16 (04) :577-592
[2]   CALCULATION AND APPLICATION OF POINT SPREAD FUNCTIONS FOR TREATMENT PLANNING WITH HIGH-ENERGY PHOTON BEAMS [J].
AHNESJO, A ;
ANDREO, P ;
BRAHME, A .
ACTA ONCOLOGICA, 1987, 26 (01) :49-56
[3]  
AHNESJO A, 1987, 9TH P INT C US COMP, P99
[4]  
BEDDAR AS, 1990, THESIS U WISCONSIN M
[5]   A PHOTON DOSE DISTRIBUTION MODEL EMPLOYING CONVOLUTION CALCULATIONS [J].
BOYER, A ;
MOK, E .
MEDICAL PHYSICS, 1985, 12 (02) :169-177
[6]   CALCULATION OF PHOTON DOSE DISTRIBUTIONS IN AN INHOMOGENEOUS-MEDIUM USING CONVOLUTIONS [J].
BOYER, AL ;
MOK, EC .
MEDICAL PHYSICS, 1986, 13 (04) :503-509
[7]   A CONVOLUTION METHOD OF CALCULATING DOSE FOR 15-MV X-RAYS [J].
MACKIE, TR ;
SCRIMGER, JW ;
BATTISTA, JJ .
MEDICAL PHYSICS, 1985, 12 (02) :188-196
[8]   GENERATION OF PHOTON ENERGY DEPOSITION KERNELS USING THE EGS MONTE-CARLO CODE [J].
MACKIE, TR ;
BIELAJEW, AF ;
ROGERS, DWO ;
BATTISTA, JJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (01) :1-20
[9]  
MACKIE TR, 1990, 10TH P INT C US COMP
[10]  
METCALFE P E, 1989, Australasian Physical and Engineering Sciences in Medicine, V12, P138