Atrial flutter ablation without use of fluoroscopy

被引:0
作者
Ventura, Alejandro [1 ]
Soriano, Lisandro [1 ]
Lopez, Marisa [1 ]
机构
[1] Cordis Inst Corazon, Serv Arritmias, Resistencia, Argentina
来源
REVISTA DE LA FEDERACION ARGENTINA DE CARDIOLOGIA | 2014年 / 43卷 / 03期
关键词
Radiofrequency ablation; Atrial flutter; Fluoroscopy;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Radiofrequency ablation procedures are usually guided by fluoroscopy, however the use of X rays is potentially harmful for both the patient and the medical and paramedical staff. Objectives: To compare the results of radiofrequency ablation performed exclusively for the navigation systems, with those made with conventional techniques in patients with typical atrial flutter Methods: Five patients with typical atrial flutter were ablated only with the assistance of the navigation systems (group I), and compared retrospectively with 21 similar cases, made with the conventional technique (group II). The endpoint of the procedure was the confirmation of bidirectional block of the cavo-tricuspid isthmus and non-inducibility of atrial flutter. We analyzed the recurrence of clinical arrhythmia and holter until 6 months after the ablation procedure. Results: No significant differences between groups with respect to the success of the procedure: Gr I = 5p (100%) vs. Gr II = 20p (95.2%). In Gr I there were no complications, and Gr II a hematoma on the puncture site. The average fluoroscopy time in the Gr II was 15 +/- 8 min, not requiring the use of it in group I. The incidence of recurrence was similar in both groups (0% vs. 4.7% Gr I Gr II). Conclusions: In patients with typical atrial flutter, radiofrequency ablation exclusively with navigation systems is a feasible and safe technique, with results comparable to the conventional technique.
引用
收藏
页码:150 / 154
页数:5
相关论文
共 50 条
  • [1] Catheter ablation of atrial fibrillation without the use of fluoroscopy
    Reddy, Vivek Y.
    Morales, Gustavo
    Ahmed, Humera
    Neuzil, Petr
    Dukkipati, Srinivas
    Kim, Steve
    Clemens, Janet
    D'Avila, Andre
    HEART RHYTHM, 2010, 7 (11) : 1644 - 1653
  • [2] No fluoroscopy for cavotricuspid isthmus-dependent right atrial flutter ablation
    Pachon, Marta
    Arias, Miguel A.
    Castellanos, Eduardo
    Puchol, Alberto
    HEART RHYTHM, 2009, 6 (03) : 433 - 434
  • [3] Ablation of atypical atrial flutter guided by the use of concealed entrainment in patients without prior cardiac surgery
    Bogun, F
    Bender, B
    Li, YG
    Hohnloser, SH
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (02) : 136 - 145
  • [4] Cavotricuspid Isthmus Catheter Ablation Without the Use of Fluoroscopy as a First-Line Treatment
    Alvarez, Miguel
    Tercedor, Luis
    Herrera, Norberto
    Munoz, Luz
    Galdeano, Ricardo S.
    Valverde, Francisca
    Penas, Rocio
    Melgares, Rafael
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 (06) : 656 - 662
  • [5] Effect of Electroanatomically Guided Versus Conventional Catheter Ablation of Typical Atrial Flutter on the Fluoroscopy Time and Resource Use: A Prospective Randomized Multicenter Study
    Hindricks, Gerhard
    Willems, Stefan
    Kautzner, Josef
    De Chillou, Christian
    Wiedemann, Michael
    Schepel, Siep
    Piorkowski, Christopher
    Risius, Tim
    Kottkamp, Hans
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 (07) : 734 - 740
  • [6] Radiofrequency ablation for cure of atrial flutter
    Kalman, JM
    Vohra, JK
    Jayaprakash, S
    Sparks, PB
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1997, 27 (06): : 653 - 657
  • [7] “Conventional” isthmus ablation without fluoroscopy
    Philipp Sommer
    Charlotte Eitel
    Gerhard Hindricks
    Christopher Piorkowski
    Journal of Interventional Cardiac Electrophysiology, 2013, 37 : 205 - 206
  • [8] "Conventional" isthmus ablation without fluoroscopy
    Sommer, Philipp
    Eitel, Charlotte
    Hindricks, Gerhard
    Piorkowski, Christopher
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2013, 37 (02) : 205 - 206
  • [9] The effect of first step right atrial mapping (FRAM) on ablation duration and fluoroscopy exposure during cavotricuspid isthmus ablation of atrial flutter
    Guan, Fu
    Saguner, Ardan M.
    Breitenstein, Alexander
    Wang, Mia
    Molitor, Nadine
    Brunckhorst, Corinna
    Wolber, Thomas
    Duru, Firat
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [10] Catheter Ablation for Treatment of Atrial Fibrillation and Supraventricular Arrhythmias Without Fluoroscopy Use: Acute Efficacy and Safety
    Saad, Eduardo B.
    Slater, Charles
    Oliveira Inacio, Luiz Antonio, Jr.
    dos Santos, Gustavo Vignoli
    Dias, Lucas Carvalho
    Montenegro Camanho, Luiz Eduardo
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2020, 114 (06) : 1015 - 1026