BLOOD-PRESSURE ANALYSIS

被引:10
作者
PENZEL, T
机构
[1] Medizinische Poliklinik, Philipps-University, Marburg, D-35033
关键词
BLOOD PRESSURE; DIAGNOSTIC METHODOLOGY; NONINVASIVE RECORDING; OBSTRUCTIVE SLEEP APNEA; SLEEP-RELATED BREATHING DISORDERS;
D O I
10.1111/j.1365-2869.1995.tb00180.x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Arterial blood pressure is influenced by sleep-related breathing disorders, As cardiovascular consequences can be diagnosed by an accurate recording and analysis of blood pressure, new recording methodologies and an approach to analysis are presented here. Invasive continuous blood pressure recording is the common reference for all methodologies, As blood pressure varies rapidly in parallel with sleep-related breathing disorders it is indispensible to record blood pressure continuously, To introduce non-invasive methodology the Finapres system was used during sleep studies; a validation study showed severe limitations, This study was followed by the validation of an improved system called Portapres, which is portable, has two finger cuffs and a hydrostatic height compensation. Analysis of continuous blood pressure in patients with sleep apnoea is carried out to detect mechanisms which influence the cardiovascular risk, Spectrum analysis of systolic blood pressure showed two different major oscillations present in patients with obstructive sleep apnoea. One oscillation (<0.06 Hz) occurs in parallel with each apnoeic episode and the other oscillation (0.2-0.4 Hz) occurs in parallel with the obstructive efforts during each apnoea and in parallel with respiration during periods of snoring, These two oscillations were so specific that the use of non-invasive continuous blood pressure recording allowed an estimation of the extent of underlying breathing disorders, and assessment of cardiovascular risk in a patient with obstructive apnoea in terms of hypertension and on the basis of ambulatory monitoring.
引用
收藏
页码:15 / 20
页数:6
相关论文
共 15 条
[1]  
Baselli G., Cerutti S., Badilini F., Biancardi L., Porta A., Pagani M., Lombardi F., Rimoldi O., Furlan R., Malliani A., Model for the assessment of heart period and arterial pressure variability interactions and of respiration influences, Med. Biol. Eng. Comput., 32, pp. 143-152, (1994)
[2]  
Carlson J., Davies R., Ehlenz K., Grunstein R., Hedner J., Podszus T., Sinoway L., Stradling J.R., Telakivi T., Zwillich C.W., Obstructive sleep apnea and blood pressure elevation: what is the relationship?, Blood Pressure, 2, pp. 166-182, (1993)
[3]  
Davies R.J., Vardi, Clarke M., Stradling J.R., Identification of sleep disruption and sleep disordered breathing from the systolic blood pressure profile, Thorax, 48, pp. 1242-1247, (1993)
[4]  
Greinke S., Brandenburg K., Penzel T., Peter J.H., von Wichert P., Spektralanalyse von Langzeitblutdruckmessungen bei Patienten mit schlafbezogenen Atmungsstörungen, Pneumologie, 47, pp. 722-725, (1993)
[5]  
Hartmann B., Bassenge E., Nichtinvasive, kontinuierliche Messung des Fingerarteriendrucks mit dem Servo‐Plethysmo‐Manometer Finapres, Herz, 14, pp. 251-259, (1989)
[6]  
Imholz B.P.M., Langewouters G.J., von Montfrans G.A., Parati G., van Goudoever J., Wesseling K.H., Wieling W., Mancia G., Feasibility of Ambulatory, Continuous 24‐hour finger arterial pressure recording, Hypertension, 21, pp. 65-73, (1993)
[7]  
Jones R.D.M., Kornberg J.P., Roulson C.J., Visram A.R., Irwin M.G., The Finapres 2300e finger cuff, Anaesthesia, 48, pp. 611-615, (1993)
[8]  
Levinson P.D., Millman R.P., Causes and consequences of blood pressure alterations in obstructive sleep apnea, Arch. Intern. Med., 151, pp. 455-462, (1991)
[9]  
Molhoek G.P., Wesseling K.H., Settels J.J., van Vollenhoven E., Weeda H.W., de Wit B., Arntzenius A.C., Evaluation of the Penaz servo‐plethysmo‐manometer for the continuous, non‐invasive measurement of finger blood pressure, Basic Res. Cardiol., 79, pp. 598-609, (1984)
[10]  
Parati G., di Rienzo M., Omboni S., Castiglioni P., Frattola A., Mancia G., Spectral analysis of 24h blood pressure recordings, Am. J. Hypertens., 6, pp. 188S-193S, (1993)