INTERLABORATORY COMPARISON OF THERMOSPRAY AND PARTICLE BEAM LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY INTERFACES - EVALUATION OF A CHLORINATED PHENOXY ACID HERBICIDE LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY ANALYSIS METHOD

被引:37
作者
JONES, TL
BETOWSKI, LD
LESNIK, B
CHIANG, TC
TEBERG, JE
机构
[1] US EPA,ENVIRONM MONITORING SYST LAB,POB 93478,LAS VEGAS,NV 89193
[2] US DOE,LAB MANAGEMENT BRANCH,GERMANTOWN,MD 20874
[3] LOCKHEED ENGN & SCI CO,LAS VEGAS,NV 89119
关键词
D O I
10.1021/es00023a006
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Seven laboratories participated in an interlaboratory evaluation of a liquid chromatography/mass spectrometry (LC/MS) method for the analysis of 10 chlorinated phenoxy acid herbicides. The focus of this evaluation was to test the intercomparability of LC/MS data obtained from two types of LC/MS interfaces [i.e., thermospray (TS) and particle beam (PB)]. Eight simulated sample extracts were sent to each laboratory for LC/MS analysis. There were statistically significant differences between interfaces in the quantitative data for all analytes except 2-(2,4,5-trichlorophenoxy)propanoic acid (silvex). Particle beam exhibited a high positive bias and a low relative standard deviation at the highest sample extract concentration range, 500-mu-g/mL, while TS showed a low bias and a low relative standard deviation at the lowest sample extract concentration range, 5-mu-g/mL. Another factor of this study was to look for any performance differences between interfaces of the same type, but differing manufacturers. A statistical difference was observed, between PB interfaces, for 2-(1-methylpropyl)-4,6-dinitrophenol (dinoseb).
引用
收藏
页码:1880 / 1884
页数:5
相关论文
共 10 条
[2]   THERMOSPRAY INTERFACE FOR LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
BLAKLEY, CR ;
VESTAL, ML .
ANALYTICAL CHEMISTRY, 1983, 55 (04) :750-754
[3]  
CREMLYN R, 1978, PESTICIDES PREPARATI, P142
[4]  
GRORUD RB, 1983, J ASSOC OFF ANA CHEM, V66, P1220
[5]  
GRORUD RB, 1984, J ASSOC OFF ANA CHEM, V67, P837
[6]  
JONES TL, 1990, ACS SYM SER, V4250, P62
[7]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY OF TRIAZINE HERBICIDES [J].
PARKER, CE ;
HANEY, CA ;
HARVAN, DJ ;
HASS, JR .
JOURNAL OF CHROMATOGRAPHY, 1982, 242 (01) :77-96
[8]   MONODISPERSE AEROSOL GENERATION INTERFACE FOR COMBINING LIQUID-CHROMATOGRAPHY WITH MASS-SPECTROSCOPY [J].
WILLOUGHBY, RC ;
BROWNER, RF .
ANALYTICAL CHEMISTRY, 1984, 56 (14) :2626-2631
[9]  
1987, SAS STAT GUIDE PERSO, P1028
[10]  
1986, TEST METHODS EVALUAT, V1